EVIS EXERA II COLONOVIDEOSCOPE OLYMPUS PCF TYPE Q180AL (UDI 04953170307720)Recalls & reported problems

Olympus Medical Systems Corp. · Class 2

All models of EVIS EXERA II COLONOVIDEOSCOPE (28)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
2

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04953170307720), received between Jan 14, 2021 and Dec 5, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Failure to Clean Adequately” (3 reports).

2 FDA recall records name this device's identifier, 2 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Jan 11, 2024Class IIOpen, Classified

    Specific repaired colonovideoscopes were assembled without an adhesive which protects them from certain physical conditions such as high levels of vibration, fluctuation in temperature or severe shock loads.

    Z-1214-2024 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

  2. Sep 25, 2023Class IIOpen, Classified

    Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead to the risk of infection

    Z-0341-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Failure to Clean Adequately3
  • Partial Blockage2
  • Device Reprocessing Problem1
  • Material Twisted/Bent1
  • Melted1
  • No Display/Image1
  • Poor Quality Image1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Patient Involvement1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 5, 2025No Display/Image; Poor Quality Image; Failure to Clean Adequately; No Display/Image; Poor Quality Image; Failure to Clean Adequately

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE COLONOVIDEOSCOPE EXHIBITED IMAGE DISTORTION (A NOISE IMAGE), NO IMAGE, FOREIGN OBJECTS COME OUT OF AIR/WATER CYLINDER, IMAGE GUIDE PROTECTOR IS DIRTY, SCOPE-CONNECTOR IS DIRTY. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23727764 ↗
  • MalfunctionNov 25, 2025Melted; Melted

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE COLON VIDEOSCOPE EXHIBITED BURNED PLASTIC ON THE DISTAL END COVER. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23648749 ↗
  • MalfunctionOct 9, 2024Failure to Clean Adequately; Failure to Clean Adequately

    IT WAS OBSERVED DURING THE DEVICE INSPECTION, THE COLONOVIDEOSCOPE EXHIBITED FOREIGN OBJECTS ON THE BENDING SECTION COVER. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20407266 ↗
  • MalfunctionMay 2, 2024Failure to Clean Adequately; Failure to Clean Adequately

    IT WAS OBSERVED THAT DURING THE DEVICE INSPECTION, THE COLONOVIDEOSCOPE AIR CHANNEL WAS UNABLE TO WORK DUE TO A CLOGGED NOZZLE. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19235021 ↗
  • MalfunctionMar 10, 2021Partial Blockage; Partial Blockage

    IT IS REPORTED WHILE PRE-CLEANING OF AN EVIS EXERA II COLONOVIDEOSCOPE, A CLIP WAS DISLODGED FROM THE INSTRUMENT CHANNEL. THERE WAS NO PATIENT CONTACT/IMPACT RELATED TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11453815 ↗
  • MalfunctionJan 14, 2021Partial Blockage; Device Reprocessing Problem; Material Twisted/Bent; Partial Blockage; Device Reprocessing Problem; Material Twisted/Bent

    IT IS REPORTED WHILE PREPARING AN EVIS EXERA II COLONOVIDEOSCOPE FOR USE, BLACK SPECS CAME OUT OF THE DEVICE WHEN IT WAS HOOKED UP TO A DRYER. THERE WAS NO PATIENT CONTACT/IMPACT RELATED TO THIS OCCURRENCE.

    Patient problems: No Patient Involvement

    MAUDE report 11174013 ↗

Other Gastroscope and accessories, flexible/rigid devices