THUNDERBEAT 5 mm, 10 cm, Inline Grip TB-0510ICRecalls & reported problems
Olympus Medical Systems Corp. · Class U
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04953170308734), received between Sep 18, 2018 and Jul 30, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- Oct 22, 2025Class IIOpen, Classified
Firm is initiating a removal due to continued reports of adverse events.
Z-1382-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Break4
- Failure to Align2
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Known Impact Or Consequence To Patient2
- Insufficient Information1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 30, 2025Break; Break
IT WAS REPORTED THE THUNDERBEAT'S TIP BROKE OFF DURING AN UNSPECIFIED THERAPEUTIC PANCREATIC PROCEDURE. THE EVENT RESULTED IN A DELAY OF THE PROCEDURE NO LONGER THAN 30 MINUTES. THERE WAS NO REPORTED PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 22664775 ↗MalfunctionJul 8, 2024Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component
IT WAS REPORTED THAT, THE TISSUE PAD OF THE ULTRASONIC SURGICAL DEVICE CAME OFF ON THE THIRD OUTPUT. IT DID NOT FALL OFF. THE ISSUE OCCURRED DURING A THERAPEUTIC LIVER RESECTION PROCEDURE. THE PROCEDURE WAS COMPLETED USING A SIMILAR DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19690200 ↗MalfunctionJun 8, 2021Break; Break
OLYMPUS MEDICAL SYSTEMS CORP. (OMSC)WAS INFORMED BY THE CUSTOMER THAT DURING THE PROCEDURE USING THE SUBJECT DEVICE, THE FOLLOWING EVENT OCCURRED. THE PROBE WAS BROKEN OFF. THE CUSTOMER PRESUMED THAT IT WAS IN CONTACT WITH THE SPREADING CLAMPS IN USE ON THE THYROID GLAND. THE INTENDED PROCEDURE WAS COMPLETED WITH ANOTHER DEVICE. THERE WAS NO PATIENT INJURY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11955958 ↗MalfunctionFeb 26, 2020Break; Break
WE RECEIVED THE FOLLOWING REPORT. DURING LIVER SURGERY, THE SUBJECT DEVICE WAS USED. THE TIP OF THE DEVICE FELL OFF INSIDE THE PATIENT. THE FRAGMENT WAS RETRIEVED. THE INTENDED PROCEDURE WAS COMPLETED. THERE WAS NO PATIENT INJURY REPORTED. THIS IS THE REPORT REGARDING THE BREAKAGE OF THE TIP.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9759686 ↗MalfunctionSep 18, 2018Failure to Align; Failure to Align
TWO OF 2. OLYMPUS WAS INFORMED THAT DURING AN ANAL POLYP EXCISION PROCEDURE, THE JAWS OF THE DEVICE WERE MISALIGNED, CAUSING THE DEVICE TO NOT WORK AFTER A FEW SECONDS. THERE WAS NO REPORTED PATIENT INJURY OR ADDITIONAL BLEEDING, AND THE PATIENT WAS REPORTED TO BE DOING WELL. THE PROCEDURE WAS COMPLETED WITH ANOTHER SIMILAR DEVICE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7887511 ↗MalfunctionSep 18, 2018Failure to Align; Failure to Align
ONE (1) OF 2. OLYMPUS WAS INFORMED THAT DURING AN ANAL POLYP EXCISION PROCEDURE, THE JAWS OF THE DEVICE WERE MISALIGNED, CAUSING THE DEVICE TO NOT WORK AFTER A FEW SECONDS. THERE WAS NO REPORTED PATIENT INJURY OR ADDITIONAL BLEEDING, AND THE PATIENT WAS REPORTED TO BE DOING WELL. THE PROCEDURE WAS COMPLETED WITH ANOTHER SIMILAR DEVICE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7887504 ↗
Other Instrument, ultrasonic surgical devices
- Harmonic ACE HARH36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical4 deaths7,609 reports
- Harmonic HARHD36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical1 recall2 deaths5,037 reports
- Harmonic ACE HAR36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical2,726 reports
- Harmonic HAR1136Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical2 deaths1,538 reports
- THUNDERBEAT 5 mm,35 cm, Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical3 recalls1,373 reports
- THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical3 recalls2 deaths1,128 reports
- THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical2 recalls1 death970 reports
- Harmonic ACE HARH23Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical935 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page