Gelweave™ 733008Recalls & reported problems

Vascutek Ltd · Gelweave Gelatin Impregnated Woven Vascular Prosthesis STRAIGHT · Class 2 · Implant

Adverse event reports
7
Deaths reported
1
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 05037881105130), received between Nov 26, 2020 and May 28, 2025 — classified as 1 death, 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Material Integrity Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Integrity Problem3
  • Contamination /Decontamination Problem1
  • Fluid/Blood Leak1
  • Insufficient Device Problem Information1
  • Labelling, Instructions for Use or Training Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Insufficient Information2
  • Post Operative Wound Infection1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 28, 2025Labelling, Instructions for Use or Training Problem; Labelling, Instructions for Use or Training Problem

    GELWEAVE STRAIGHT RECEIVED BY CUSTOMER WITH LABELS MISSING FROM INSIDE CARTON.( ONLY ONE WAS IN THERE RATHER THAN THE NORMAL X 4 STICKERS) GRAFT WAS IMPLANTED WITH NO ISSUES, THE ONE LABEL PRESENT WAS USED. HOSPITALS USE THE SPARE STICKERS PROVIDED ON DOCUMENTATION AS NEEDED, BUT IN THIS CASE, THEY ONLY HAD ONE. THIS REPORT IS BEING SUBMITTED AS FOLLOW UP #1 FOR MANUFACTURING REPORT NUMBER 9612515-2025-00055 TO PROVIDE EVENT CLOSURE INFORMATION FOR TAG0249.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22094860 ↗
  • DeathFeb 13, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    GRAFT WAS LEAKING BLOOD DURING PROCEDURE. PHYSICIAN STATED IT WAS NOT HANDLING BLOOD THE WAY IT NORMALLY WOULD.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 18693353 ↗
  • InjuryAug 4, 2022Contamination /Decontamination Problem; Contamination /Decontamination Problem

    THIS EVENT WAS REPORTED VIA THE PANTHER STUDY PROGRAMME AS FOLLOWS: A GELWEAVE STRAIGHT GRAFT WAS UTILISED AS PART OF AN ECMO PROCEDURE (ECMO CANNULATION) ON (B)(6) 2020. ON (B)(6) 2020 A FESTERING WOUND INFECTION WAS REPORTED . ON (B)(6) 2020 THE GELWEAVE GRAFT WAS EXPLANTED.. THE EVENT WAS INDICATED AS DEVICE, PATIENT AND PROCEDURE RELATED.

    Patient problems: Post Operative Wound Infection

    MAUDE report 15162582 ↗
  • MalfunctionJun 13, 2022Fluid/Blood Leak; Fluid/Blood Leak

    EVENT WAS REPORTED AS FOLLOWS: GRAFT SOAKED IN NORMAL SALINE FOR 3 MINS PRIOR TO REMOVAL AND USED FOR FEMORAL ARTERY ANASTOMOSIS FOR CARDIOPULMONARY BYPASS CANNULATION. BLOOD CONSTANTLY LEAKING THROUGH PERMEABLE GELWEAVE GRAFT. THE PATIENT WAS PROFUSELY BLEEDING OUT OF THE FEMORAL ARTERY FOR THE DURATION OF THE CASE. THE RESULT WAS HAEMOLYSIS, CONSTANT BLOOD LOSS AND INTERRUPTION TO THE SURGICAL PROCEDURE. PATIENT WAS UNDERGOING CORONARY BYPASS AND AORTIC VALVE REPLACEMENT. ESTIMATED BLOOD LOSS >250ML.

    Patient problems: Insufficient Information

    MAUDE report 14673661 ↗
  • MalfunctionAug 13, 2021Material Integrity Problem; Material Integrity Problem

    ON (B)(6) 2021 THE FACILITY THAT WAS USING THE GELWEAVE GRAFT REPORTED THAT IT WAS LEAKING (POROUS). THE EXCESS BLOOD WAS SUCTIONED AWAY AND THE PROCEDURE WAS COMPLETED WITHOUT FURTHER ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12317323 ↗
  • MalfunctionMar 1, 2021Material Integrity Problem; Material Integrity Problem

    ON (B)(6) 2021, THE SURGEON UTILISED A GELWEAVE STRAIGHT GRAFT FOR AXILLARY CANNULATION INTO A PATIENT. APPROXIMATELY 90MINS INTO THE PROCEDURE THE GELWEAVE BRANDED GRAFT STARTED TO LEAK (BLOOD WAS LEAKING ON TO THE FLOOR). THE GRAFT WAS WIPED, BUT IT CONTINUED TO LEAK. THE GRAFT WAS UNDER PRESSURE (AT AN UNKNOWN LEVEL) AND THE PATIENTS TEMPERATURE WAS AT 34 DEGREES. NO INTERVENTION WAS PERFORMED BY THE CLINICAL TEAM DURING USE AND NO NEGATIVE EFFECT HAS BEEN REPORTED WITH REGARDS TO THE PATIENTS CONDITION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11392043 ↗
  • MalfunctionNov 26, 2020Material Integrity Problem; Material Integrity Problem

    REPORTED TO VASCUTEK LTD. AS FOLLOWS: PATIENT WAS BEING PLACED ON ECMO, AND PRODUCT WAS USED TO GAIN ARTERIAL ACCESS FOR BYPASS. ONCE THE PATIENT WAS PLACED ON BYPASS IT WAS NOTED THAT THERE WAS SIGNIFICANT BLOOD LEAKAGE THROUGH THE GRAFT FABRIC. SURGEON INSPECTED THE GRAFT SUTURE LINE TO DETERMINE WHETHER IT WAS LOCATED THERE, BUT DETERMINED THE LEAKAGE WAS OCCURRING THROUGH THE ENTIRE GRAFT MATERIAL. SURGEON HAD TO INSERT A CANNULA INTO THE GRAFT TO MINIMISE THE BLOOD LOSS FROM THE ARTERY. PATIENT LOST APPROXIMATELY 5L OF BLOOD DURING THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10910331 ↗

Other PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER devices