Gelweave™ 732810108/8S4Recalls & reported problems
Vascutek Ltd · Gelweave Gelatin Impregnated Woven Vascular Prosthesis COSELLI THORACOABDOMINAL GRAFT · Class 2 · Implant
All models of Gelweave (47)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05037881107257), received between Mar 10, 2026 and Mar 10, 2026 — classified as 1 injury.
1 other recall cover devices cleared under the same FDA submission (K090987, K162794); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Pseudoaneurysm1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 10, 2026Adverse Event Without Identified Device or Use Problem
EVENT REPORTED FROM PANTHER STUDY (NCT04545502) AS PSEUDOANEURYSM. THE PATIENT WAS A 53-YEAR-OLD, BLACK, MALE WITH CHRONIC DISSECTION, UNDERWENT OPEN SURGICAL REPAIR OF THE THORACOABDOMINAL AORTA WITH A GELWEAVE THORACOABDOMINAL COSELLI GRAFT ON (B)(6) 2025. POST-OPERATIVELY (ON POD 121 - ON (B)(6) 2026), THE PATIENT PRESENTED WITH THE SERIOUS ADVERSE EVENT OF PSEUDOANEURYSM. CT ANGIOGRAPHY SHOWED ARTERIAL EXTRAVASATION FROM THE DISTAL AORTIC GRAFT WITH ENLARGING LEFT PLEURAL HEMATOMA. THE PATIENT UNDERWENT EMERGENT TEVAR AND EVAR ON (B)(6) 2026, AND THE EVENT WAS CONSIDERED RESOLVED WITH SEQUELAE. THE SITE CONFIRMED THAT THE REINTERVENTION WAS NOT REQUIRED AS A RESULT OF ANY DEVICE DEFICIENCY.
Patient problems: Pseudoaneurysm
MAUDE report 24555356 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K090987, K162794. One submission often covers many models, so check the product and lot details in each record.
- Z-2542-2021 · Jul 8, 2021 · TerminatedThe Instructions for Use (IFU) for: Gelsoft Plus Bifurcate, Gelsoft Plus Ax-Fem, GelsoftPlus ERS Ax-Fem, Gelweave Straight, Gelweave Trifurcate, Gelweave Ant-Flo, and Gelweave Val
Other PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER devices
- Cardioroot HEWROOT0030Intervascular Sas · Prosthesis, Vascular Graft, Of 6mm And Greater Diameter1 recall2 deaths13 reports
- FLIXENE SLIDER GDS 25058Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall13 reports
- ADVANTA SLIDER GDS 22114Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall11 reports
- Cardioroot HEWROOT0032Intervascular Sas · Prosthesis, Vascular Graft, Of 6mm And Greater Diameter1 recall2 deaths10 reports
- FLIXENE SLIDER GDS 25129Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall9 reports
- ADVANTA SLIDER GDS 22222Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall8 reports
- FLIXENE SLIDER GDS 25137Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall8 reports
- FLIXENE SLIDER GDS 25138Atrium Medical Corporation · PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER1 recall7 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page