Vascutek Ltd · Gelsoft Plus Gelatin Impregnated Knitted Vascular Prosthesis STRAIGHT · Class 2 · Implant

All models of Gelsoft Plus (19)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05037881115221), received between Jul 2, 2024 and Nov 11, 2024 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Off-Label Use” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K162803, K955230); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Off-Label Use2
  • Material Integrity Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 11, 2024Off-Label Use; Off-Label Use

    EVENT DATE: 19 OCT 24, IMPLANT DATE: ON (B)(6) 2024. EVENT WAS REPORTED AS WEAVING DEFECTS. THE SURGICAL GRAFT WAS USED AS A CIRCULATION LINE FOR AORTIC REPLACEMENT PROCEDURE, AND AFTER CLAMP RELEASED, SURGEON FOUND BLOOD EJECT FROM THE SURFACE OF SURGICAL GRAFT (NOT THE ANASTOMOSIS SITE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20651871 ↗
  • MalfunctionJul 16, 2024Off-Label Use; Off-Label Use

    EVENT REPORTED ON (B)(6) 2024. IMPLANT DATE: (B)(6) 2024, EXPLANT DATE: (B)(6) 2024. AS REPORTED: THE SURGICAL GRAFT WAS USED AS A CIRCULATION LINE FOR AORTIC REPLACEMENT PROCEDURE, AND AFTER CLAMP RELEASED, SURGEON FOUND BLOOD SEEPAGE FROM THE SURFACE OF SURGICAL GRAFT (NOT THE ANASTOMOSIS SITE). EVENT WAS MARKED AS DEVICE RELATED BY THE SITE (DUE TO POSSIBLE WEAVING DEFECTS OR GELATINE FAIL) PATIENT RELEVANT MEDICAL CONDITIONS / PATIENT'S DIAGNOSIS: DAA AORTIC REPLACEMENT SURGERY, (REQUESTED CLARIFICATION OF DAA FROM THE REPORTING SITE). THIS REPORT IS BEING SUBMITTED AS A FOLLOW UP 1 FOR MANUFACTURING REPORT #9612515-2024-00049 TO PROVIDE EVENT CLOSURE INFORMATION FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19749536 ↗
  • MalfunctionJul 2, 2024Material Integrity Problem; Material Integrity Problem

    THE SURGICAL GRAFT WAS USED AS A CIRCULATION LINE FOR MV MITRAL VALVE REPAIR PROCEDURE, AND AFTER CLAMP RELEASED, SURGEON FOUND BLOOD LEAKAGE FROM THE SURFACE OF SURGICAL GRAFT (NOT THE ANASTOMOSIS SITE). THE PROBLEM OF BLOOD LEAKAGE FROM THE SURFACE OF SURGICAL GRAFT, SURGEON HAS SUTURED THE BLEEDING HOLE TO STOP THE LEAKAGE. THE PATIENT IS STABLE. EVENT REPORTED AS DEVICE RELATED & POSSIBLY PROCEDURE / PRE-EXISTING CONDITION.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 19655886 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K162803, K955230. One submission often covers many models, so check the product and lot details in each record.

  • Z-2542-2021 · Jul 8, 2021 · Terminated
    The Instructions for Use (IFU) for: Gelsoft Plus Bifurcate, Gelsoft Plus Ax-Fem, GelsoftPlus ERS Ax-Fem, Gelweave Straight, Gelweave Trifurcate, Gelweave Ant-Flo, and Gelweave Val

Other PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER devices