Skip to content

Biotronik Passeo-35 HP 7/40/75Recalls & reported problems

Creagh Medical Limited · Class 2

All models of Biotronik Passeo-35 HP (9)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05391525781525), received between Aug 5, 2025 and Aug 5, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 5, 2025Fracture; Fracture

    THE HIGH-PRESSURE BALLOON WAS USED IN A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) PROCEDURE FOR TREATMENT OF A MODERATELY CALCIFIED LESION (STENOSIS DEGREE: 70%) IN A MODERATELY TORTUOUS BID-BRACHIAL ARTERY. THE TARGET VESSEL ALSO HAD A CALCIFICATION DEGREE OF APPROXIMATELY 70%. BALLOON INFLATION WAS ATTEMPTED AFTER PLACING INTO THE TARGET LESION. THE BALLOON BURST AT THE PRESSURE OF 21 ATM (RATED BURST PRESSURE WAS 23 ATM). THE BALLOON WAS PREPPED PER IFU. THERE WAS NO INDICATION OF ANY DAMAGE DURING DEVICE PREPARATION. NEGATIVE PRESSURE WAS CONFIRMED TO BE HELD DURING LOADING AND ADVANCING TO THE TARGET LESION AND THERE WAS NO LOSS OF NEGATIVE PRESSURE. THE DEVICE WAS NOT TORQUED OR TWISTED DURING LOADING. THE LESION LENGTH WAS NOTED TO BE APPROXIMATELY 30MM WITH A VESSEL DIAMETER OF 7MM. THERE WAS NO PATIENT INJURY. NO PARTS OF THE BALLOON REMAINED IN THE PATIENT. THE REPORTED ISSUE RESULTED IN A PROCEDURE DELAY OF APPROXIMATELY FIVE MINUTES. NO ADDITIONAL MEDICAL INTERVENTION WAS REQUIRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22721174 ↗

Other Catheter, Angioplasty, Peripheral, Transluminal devices

All Catheter, Angioplasty, Peripheral, Transluminal devices →