Skip to content

Advance Serenity™ 14 SER14-150-20-100Recalls & reported problems

Creagh Medical Limited · Advance Serenity 14 2mm x 10cm x 150cm · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05391525784762), received between Jul 21, 2021 and Feb 8, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak1
  • Fracture1
  • Material Rupture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 8, 2024Fluid/Blood Leak; Fracture; Fluid/Blood Leak; Fracture

    THE SITE REPORTED THEY USED TWO BALLOONS IN A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) PROCEDURE OF THE ANTERIOR TIBIAL ARTERY. EACH BALLOON WAS REPORTED TO RUPTURE ON INITIAL INFLATION. THE BALLOONS WERE PREPARED PER IFU AND USED IN COORDINATION WITH AN 0.014" GUIDEWIRE AND 6F SHEATH. THE DEGREE OF STENOSIS IN THE TARGET VESSEL WAS SEVERE. BOTH BALLOONS RUPTURED DURING INITIAL INFLATION. THE PROCEDURE WAS SUCCESSFULLY WITH A COMPETITORS DEVICE. GOOD DISTAL FLOW WAS ULTIMATELY ESTABLISHED. NO FURTHER MEDICAL INTERVENTION WAS REQUIRED. THERE WAS NOT PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18673151 ↗
  • MalfunctionJul 21, 2021Material Rupture; Material Rupture

    FOLLOW-UP REPORT TO SUBMIT ADDITIONAL INFORMATION NOT KNOWN AT TIME OF INITIAL SUBMISSION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12205943 ↗

Other Catheter, Angioplasty, Peripheral, Transluminal devices

All Catheter, Angioplasty, Peripheral, Transluminal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page