WorkMate Claris™ H700131Recalls & reported problems
St. Jude Medical, Inc. · ECG Cable Set, Radiopaque · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05415067001313), received between Nov 1, 2024 and Nov 1, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Signal Artifact/Noise” (1 report).
3 other recalls cover devices cleared under the same FDA submission (K132073, K210392); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Signal Artifact/Noise1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 1, 2024Signal Artifact/Noise; Signal Artifact/Noise
DURING AN AV NODE ABLATION PROCEDURE, THERE WAS NOISE ON SURFACE ECGS AND ABLATION CATHETER WHILE USING THE ENSITE PRECISION MAPPING SYSTEM RESULTING IN CANCELLATION OF THE PROCEDURE. THE RECORDCONNECT WAS BYPASSED, BUT THE ISSUE DID NOT RESOLVE. THE RIGHT LEG PATCH, ECG LEADS, CATHETER, AND CONNECTING CABLE WERE REPLACED, BUT THE ISSUE DID NOT RESOLVE. THE CABLE MANAGEMENT AND NOTCH FILTER WERE CHECKED, AND THE SYSTEM WAS REBOOTED, BUT THE ISSUE DID NOT RESOLVE. THE PROCEDURE WAS CANCELLED DUE TO THIS ISSUE. LATER THE ECG CABLE SET WAS REPLACED AND THE ISSUE WAS RESOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20589395 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K132073, K210392. One submission often covers many models, so check the product and lot details in each record.
- Z-1855-2021 · May 5, 2021 · TerminatedWorkMate Claris v.1.2 Upgrade Kits, Model Numbers H800007 and H800012
- Z-1853-2021 · May 5, 2021 · Terminatedv.1.2 Upgrade Kit or v.1.2 upgrade installed on WorkMate Claris System, Model H700123. The WorkMate Claris" System is a computer-based electrocardiographic recording and monitorin
- Z-1854-2021 · May 5, 2021 · Terminatedv.1.2 Upgrade Kit or v.1.2 upgrade installed on WorkMate Claris" System Display, Model H700124, The WorkMate Claris" System is a computer-based electrocardiographic recording an
Other COMPUTER, DIAGNOSTIC, PROGRAMMABLE devices
- ZIO AT Patch A100A100XIrhythm Technologies, Inc. · Computer, Diagnostic, Programmable1 recall14 deaths629 reports
- CARTO 3 FG540000Biosense Webster (Israel) Ltd. · Computer, diagnostic, programmable1 death437 reports
- Sensis 10764561Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE5 recalls8 reports
- Sensis Vibe Hemo 11007641Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death22 reports
- Sensis Vibe Combo 11007642Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death6 reports
- Change Healthcare Cardiology Hemo 15.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable4 recalls1 report
- Change Healthcare Cardiology Hemo 15.0.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls1 death1 report
- Change Healthcare Cardiology Hemo 14.3.2Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.