EnSite Precision™ Link, Sensor Enabled™ H702475Recalls & reported problems

St. Jude Medical, Inc. · Link · Class 2

Adverse event reports
16
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 05415067024756), received between Jun 7, 2019 and Jun 26, 2024 — classified as 16 malfunctions.

The most frequently reported specific device problem is “Sparking” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Sparking5
  • Communication or Transmission Problem4
  • Thermal Decomposition of Device3
  • Arcing2
  • Device Emits Odor1
  • Output Problem1
  • Smoking1

Patient problems

  • No Clinical Signs, Symptoms or Conditions10
  • No Consequences Or Impact To Patient5
  • No Patient Involvement1

Recent adverse event reports

The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 26, 2024Communication or Transmission Problem; Communication or Transmission Problem

    DURING THE ATRIAL FIBRILLATION PROCEDURE, COMMUNICATION ISSUES RESULTED IN THE PROCEDURE BEING CANCELLED. IT WAS NOTED THAT INTRACARDIAC SIGNALS WERE LOST. AN ATTEMPT TO CONTACT TECHNICAL SUPPORT WAS MADE BUT WITHOUT SUCCESS. THE ECG WAS CONNECTED MORE SECURELY WHICH RESOLVED THE ISSUE, BUT THE PROCEDURE HAD ALREADY BEEN CANCELLED. THERE WERE NO ADVERSE CONSEQUENCES FOR THE PATIENT AND IT IS UNKNOWN IF THE PROCEDURE HAS BEEN RESCHEDULED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19615699 ↗
  • MalfunctionMar 29, 2024Thermal Decomposition of Device; Thermal Decomposition of Device

    DURING DEVICE PREPARATION FOR A PULMONARY VEIN ISOLATION PROCEDURE, IT WAS REPORTED THE PRECISION LINK POWER SUPPLY PORT APPEARED DAMAGED AND CHARRED. WHEN TRYING TO RECONNECT, IT WAS PLUGGED IN BUT DID NOT TURN ON. IT IS NOTED THAT THE POWER CORD ALSO HAD A LOOSE FIT WITHIN THE PORT. THE PROCEDURE WAS COMPLETED WITHOUT USING THE FIELD FRAME AND THE ENSITE PRECISION LINK. THERE WERE NO REPORTED ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19003648 ↗
  • MalfunctionFeb 17, 2023Communication or Transmission Problem; Communication or Transmission Problem

    RELATED MANUFACTURING REFERENCE: 2184149-2023-00040. DURING THE SVT ABLATION PROCEDURE, IT WAS NOTED THAT THERE WAS NO MAGNETIC LOCATION WHICH CAUSED DELAYS TO TREATMENT. A LINK AND FIELD FRAME FROM A SECOND SYSTEM WERE USED AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16400694 ↗
  • MalfunctionJul 26, 2022Output Problem; Output Problem

    RELATED MANUFACTURING REF: 2184149-2022-00178, 3008452825-2022-00530. DURING A FOCAL ATRIAL TACHYCARDIA PROCEDURE, A PROCEDURE DELAY OCCURRED. THE TACTICATH SE WOULD NOT REGISTER CONTACT FORCE AND ANOTHER WAS OBTAINED TO RESOLVE THE ISSUE. NEXT, THE TACTISYS WOULD NOT CONNECT AS IT WAS THOUGHT TO HAVE OVERHEATED. THE TACTISYS WAS REPLACED AND THE ISSUE WAS RESOLVED. ADDITIONALLY, THE ENSITE PRECISION LINK PROVIDED ERROR MESSAGES TO ENSITE PRECISION. IT WAS REPLACED WITH A DIFFERENT PRECISION LINK, WHICH RESOLVED THE ISSUE. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15102984 ↗
  • MalfunctionMar 28, 2022Communication or Transmission Problem; Communication or Transmission Problem

    DURING THE ATRIAL FIBRILLATION ENSITE PRECISION CASE USING SE FIELD SCALING, A PROLONGED PROCEDURE OCCURRED. THE COLLECTED GEOMETRY CHANGED TO A FLAT, LONG PICTURE AND THE ABLATION CATHETERS OPTICAL PULL TOGETHER. SE POINTS WERE COLLECTED AROUND THE CHAMBER AND THE PRS WAS LOCATED IN A CORRECT POSITION. THE SYSTEM WAS RESTARTED FOUR TIMES AND ALL CABLE CONNECTIONS WERE CONFIRMED, WITHOUT SE FIELD SCALING THE ISSUE WAS RESOLVED. THE PROCEDURE WAS COMPLETED WITHOUT ANY PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13932448 ↗
  • MalfunctionFeb 24, 2022Arcing; Arcing

    THIS REPORT IS TO ADVISE OF AN EVENT OBSERVED DURING ANALYSIS CONFIRMING TWO DISCOLORED/BLACKENED PINS WHICH WAS ISOLATED TO AN ELECTRICAL ARC AT THE REAR POWER INLET CONNECTOR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13591638 ↗
  • MalfunctionOct 25, 2021Communication or Transmission Problem; Communication or Transmission Problem

    DURING A VENTRICULAR TACHYCARDIA ABLATION PROCEDURE, A PROLONGED PROCEDURE OCCURRED DUE TO EXPERIENCING AN ERROR MESSAGE WITH THE SYSTEM AND THE TROUBLESHOOTING INVOLVED IN ORDER TO RESOLVE THE ISSUE. WHEN ALL THE EQUIPMENT WAS CONNECTED, THE PRECISION LINK DID NOT CONNECT AND THE SYSTEM DISPLAYED AN ERROR MESSAGE. MULTIPLE TROUBLESHOOTING EFFORTS WERE CONDUCTED, AND LASTLY, WHEN THE PRECISION LINK WAS EXCHANGED, THE ISSUE WAS RESOLVED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12691798 ↗
  • MalfunctionSep 2, 2021Thermal Decomposition of Device; Thermal Decomposition of Device

    THIS REPORT IS BEING SUBMITTED BASED ON ANALYSIS WHICH REVEALED A THERMAL EVENT OCCURRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12416144 ↗
  • MalfunctionJul 12, 2021Smoking; Smoking

    DURING TROUBLESHOOTING OUTSIDE OF A PROCEDURE, WHEN THE FIELD FRAME CABLE WAS CONNECTED TO THE PRECISION LINK AND FIELD FRAME, THE PRECISION LINK STARTED TO SMOKE AND EMIT A BURNING ODOR. THE CABLE WAS IMMEDIATELY DISCONNECTED. THERE WAS NO PATIENT INVOLVED AND THE USER WAS NOT HARMED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12149065 ↗
  • MalfunctionMar 25, 2021Sparking; Sparking

    PRIOR TO THE PROCEDURE, THERE WAS SPARKING AT THE PRECISION LINK POWER SUPPLY. THE PRECISION LINK POWER SUPPLY WAS DAMAGED AND SPARKED WHEN IT WAS PLUGGED INTO THE PRECISION LINK. THE LOCKING COLLAR ON THE POWER SUPPLY WAS NOTED TO BE MISSING. IT WAS NOT MISSING AT THE PREVIOUS CASE ON (B)(6) 2021.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11570158 ↗
  • MalfunctionJan 7, 2021Thermal Decomposition of Device; Device Emits Odor; Thermal Decomposition of Device; Device Emits Odor

    DURING THE PROCEDURE, THE PRECISION LINK SMELLED OF BURNING AND DISPLAYED ARCING WHEN POWERED ON. AN ARCED/BLACKENED SPOT IS VISIBLE ON ONE OF THE SPOTS WHERE THE 4 PIN PRONG IS INSERTED FOR POWER. THE COVER WAS TAKEN OFF THE LINK AND NO INTERNAL DAMAGE WAS NOTED OTHER THAN THE POWER CONNECTION. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT OR THE USER.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 11132560 ↗
  • MalfunctionFeb 24, 2020Sparking; Sparking

    WHILE CONNECTING THE PRECISION LINK POWER CABLE TO THE POWER OUTLET SPARKS WERE DETECTED. BLACK RESIDUE WAS OBSERVED ON THE POWER SUPPLY. THERE WERE NO PATIENT OR USER ADVERSE CONSEQUENCES DUE TO THE SPARK AND THE PRECISION LINK WAS NOT USED FOR THE PROCEDURE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9747040 ↗
  • MalfunctionDec 30, 2019Sparking; Sparking

    DURING SET UP FOR A PROCEDURE THE ENSITE PRECISION LINK POWER SUPPLY CABLE FELL APART AND SPARKED. A DIFFERENT POWER SUPPLY WAS UTILIZED FOR THE SCHEDULED PROCEDURE. THERE WERE NO USER CONSEQUENCES.

    Patient problems: No Patient Involvement

    MAUDE report 9531935 ↗
  • MalfunctionAug 6, 2019Sparking; Sparking

    DURING HARDWARE SET UP PRIOR TO THE PROCEDURE, A SPARK WAS NOTED WHEN PLUGGING IN THE POWER SUPPLY OF THE PRECISION LINK. TRACES OF POWDER WERE VISIBLE AT THE CONNECTION BETWEEN THE CABLE AND THE CONNECTOR. THE PROCEDURE WAS CANCELLED AND RESCHEDULED FOR A LATER DATE. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT OR USER.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8866163 ↗
  • MalfunctionAug 1, 2019Sparking; Sparking

    RELATED MANUFACTURER REFERENCE: 2184149-2019-00143. DURING PREPARATION, A SPARK WAS NOTED WHEN USING THE PRECISION LINK POWER INPUT. SOME OF THE PINS APPEARED TO HAVE FUSED TOGETHER. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8851348 ↗
  • MalfunctionJun 7, 2019Arcing; Arcing

    DURING SYSTEM SET UP, THE PRECISION LINK APPEARED CHARRED AT THE AC INPUT AND BLACK RESIDUE WAS NOTED. NO SMOKE OR FIRE WAS PREVIOUSLY OBSERVED. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8678483 ↗

Other COMPUTER, DIAGNOSTIC, PROGRAMMABLE devices

All COMPUTER, DIAGNOSTIC, PROGRAMMABLE devices →