EnSite™ ENSITE-R-DWS-1.1Recalls & reported problems
St. Jude Medical, Inc. · X EP System Display Workstation · Class 2
All models of EnSite (37)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05415067037756), received between Apr 8, 2026 and Apr 8, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Application Program Freezes or Fails to Launch” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Application Program Freezes or Fails to Launch1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 8, 2026Application Program Freezes or Fails to Launch
DURING AN ATRIAL FIBRILLATION PROCEDURE, THERE WAS A PROCEDURAL DELAY. IN VOXEL MODE, ON ENSITE X 3.1.1 SOFTWARE, IT WAS NOTED THAT THE SYSTEM SUDDENLY BECAME CHOPPY AND ABNORMAL WHEN THE STUDY WAS ENTERED AND ANY OPERATION WAS ATTEMPTED TO BE PERFORMED. THE SURFACE AND INTRACARDIAC ELECTROGRAMS DISPLAYED AS A MAGENTA-COLORED BASELINE, AND THE SYSTEM FROZE. THE CONNECTIONS WERE CHECKED AND CONFIRMED TO BE CORRECT. A FORCED LOGOUT OF THE SYSTEM WAS PERFORMED USING CTRL + ALT + DELETE AND THE SYSTEM WAS REBOOTED, BUT THE ISSUE PERSISTED EVEN AFTER FIVE TO TEN REBOOTS. WHEN SHUTTING DOWN THE SYSTEM, AN ERROR STATING "HARDWARE ERROR" DISPLAYED JUST BEFORE THE SYSTEM POWERED OFF. THE ISSUE INTERFERED WITH LOADING PRESETS, ADDING CATHETERS, AND PERFORMING SET METAL AND INITIATING MAPPING. WHEN THE ADVISOR HD GRID X AND TACTIFLEX CATHETERS WERE AUTOMATICALLY RECOGNIZED, THE SYSTEM WAS ABLE TO MAINTAIN STABLE PERFORMANCE, AND MINIMAL NAVIGATION WAS POSSIBLE IN NAVX MODE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY BY PERFORMING ONLY PVI IN NAVX MODE UNDER FLUOROSCOPIC AND ICE GUIDANCE. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24817227 ↗
Other Computer, diagnostic, programmable devices
- ZIO AT Patch A100A100XIrhythm Technologies, Inc. · Computer, Diagnostic, Programmable1 recall14 deaths629 reports
- CARTO 3 FG540000Biosense Webster (Israel) Ltd. · Computer, diagnostic, programmable1 death437 reports
- Sensis 10764561Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE5 recalls8 reports
- Sensis Vibe Hemo 11007641Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death22 reports
- Sensis Vibe Combo 11007642Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death6 reports
- Change Healthcare Cardiology Hemo 15.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable4 recalls1 report
- Change Healthcare Cardiology Hemo 15.0.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls1 death1 report
- Change Healthcare Cardiology Hemo 14.3.2Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page