Skip to content

endomina platformRecalls & reported problems

Endo Tools Therapeutics · endomina platform primary packaging (x1) · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05425029282018), received between Jul 18, 2023 and Jul 18, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Improper or Incorrect Procedure or Method1

Patient problems

  • Gastrointestinal Hemorrhage1
  • Perforation of Vessels1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 18, 2023Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    DURING AN INTERVENTION USING THE ENDOMINA(R) SYSTEM ON (B)(6), 2023, AN ARTERIAL BLEEDING OCCURRED. INTRA-PROCEDURAL HEMOSTASIS WAS SUCCESSFULLY PERFORMED, AND THE PROCEDURE WAS APPROPRIATELY ABORTED. THE DEVICE WAS THROWN AWAY BY THE MEDICAL STAFF IN CHARGE OF THE PROCEDURE AND COULD NOT BE RETRIEVED. THE PATIENT WAS DISCHARGED THE NEXT DAY WITHOUT PROBLEM, AS INITIALLY PLANNED. THE VENDOR'S REPRESENTATIVE ONLY HAD CONFIRMATION OF THE PATIENT STATE OF HEALTH AND DAY OF DISCHARGE THROUGH A PHONE CALL TWO DAYS LATER. SINCE THE INCIDENT CONTACT WAS ESTABLISHED WITH THE SITE AND THE PHYSICIAN AT LEAST ONCE A WEEK. NO OTHER CONCERNS WERE RAISED. ON (B)(6), 2023, COMPANY RECEIVED A MEDWATCH FROM MAYO CLINIC REFERENCE (B)(4). CONTEXT: THE ENDOMINA CASE WAS THE FIRST ONE IN THIS HOSPITAL, THEREFORE, A PHYSICIAN EXPERT IN THE TECHNIQUE AND A VENDOR FIELD SPECIALIST CAME FOR PROCTORING. IT WAS IDENTIFIED THAT THE BLEEDING WAS RELATED TO THE USE OF THE DEVICES AND HAD BEEN CAUSED BY A USER ERROR. ROOT CAUSE ANALYSIS: THE DEVICE RESPONSIBLE FOR THE BLEEDING WAS THE ENDOMINA(R) PLATFORM/ AFTER UNBENDING THE ARM (BENDABLE COIL) OF THE PLATFORM, SOME TISSUE WAS CAUGHT INTO THE SYSTEM WITHOUT BEI

    Patient problems: Gastrointestinal Hemorrhage; Perforation of Vessels

    MAUDE report 17340670 ↗

FDA clearance and classification

Cleared through 510(k) K211309 on Dec 7, 2021 (decision: Substantially Equivalent). Submitted by Endo Tools Therapeutics S.A. as “endomina system”. The FDA review took 221 days. FDA record ↗

The FDA regulates product code OCW (endoscopic tissue approximation device) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the endomina platform

Has the endomina platform been recalled?

No FDA recall record in our data names this exact device identifier (DI 05425029282018), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the endomina platform?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 18, 2023. That report lists device problem “Improper or Incorrect Procedure or Method” (1); patient problems “Gastrointestinal Hemorrhage” (1) and “Perforation of Vessels” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the endomina platform?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the endomina platform FDA approved?

It was cleared through 510(k) K211309 on Dec 7, 2021. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the endomina platform MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.

Who makes the endomina platform, and is it still sold?

The FDA's device database lists Endo Tools Therapeutics as the company responsible for it (brand endomina platform, model endomina platform). Its record shows it as in commercial distribution.