FLOW-i C30 6677300Recalls & reported problems

Maquet Critical Care AB · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

3 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
8
Deaths reported
0
Injuries reported
2
Recalls naming it
3

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07325710001363), received between Oct 23, 2019 and Apr 17, 2025 — classified as 2 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Output Problem” (6 reports).

3 FDA recall records name this device's identifier, 3 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Jun 24, 2026Open, Classified

    Events observed where anesthetic agent was not delivered when the vaporizer was activated. Failure to deliver the anesthetic agent may result in the patient receiving insufficient anesthesia and may lead to intraoperative awareness.

    Z-2860-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

  2. Dec 11, 2023Open, Classified

    Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous situation.

    Z-0988-2024 · Root cause: Software design · Recall details · FDA record ↗

  3. Dec 22, 2022Open, Classified

    Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia.

    Z-0959-2023 · Root cause: Software Design Change · Recall details · FDA record ↗

Most reported problems

Device problems

  • Output Problem6
  • Unexpected Therapeutic Results2

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • Awareness During Anesthesia2

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 17, 2025Output Problem; Output Problem

    IT WAS REPORTED THAT THE ANESTHESIA SYSTEM STOPPED VENTILATING THE PATIENT. AN ALARM FOR HIGH AIRWAY PRESSURE WAS PRESENT IN THE LOG. THERE WAS NO PATIENT HARM. MANUFACTURER'S REFERENCE NUMBER: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21856739 ↗
  • MalfunctionNov 26, 2024Output Problem; Output Problem

    MANUFACTURER'S REFERENCE ID: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20784626 ↗
  • MalfunctionSep 13, 2024Output Problem; Output Problem

    IT WAS REPORTED THAT THERE WAS AN INCREASE IN MEASURED FICO2 DURING SURGERY. THERE WAS NO PATIENT HARM. MANUFACTURER'S REFERENCE NUMBER: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20211038 ↗
  • MalfunctionJul 18, 2024Output Problem; Output Problem

    MANUFACTURER'S REFERENCE #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19770356 ↗
  • MalfunctionNov 2, 2023Output Problem; Output Problem

    IT WAS REPORTED THAT WHILE THE ANESTHESIA SYSTEM WAS IN USE SEVERAL ALARMS FOR LEAKAGE WERE GENERATED. THERE WAS NO PATIENT HARM. MANUFACTURER'S REFERENCE #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18054218 ↗
  • MalfunctionMay 11, 2023Output Problem; Output Problem

    MANUFACTURER'S REFERENCE NUMBER: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16910105 ↗
  • InjuryOct 23, 2019Unexpected Therapeutic Results; Unexpected Therapeutic Results

    THE ANESTHESIA WORK STATION WAS CONNECTED TO A PATIENT AND THE TREATMENT WAS RUNNING IN AUTOMATIC VENTILATION WITH AUTOMATIC GAS CONTROL (AGC) SELECTED. THE ANESTHETIC AGENT WAS DELIVERED IN THE BEGINNING OF THE TREATMENT BUT AFTER CHANGE FROM SEVOFLURANE (VAPORIZER IN SLOT 1) TO DESFLURANE (VAPORIZER IN SLOT 2) THE AGENT DELIVERY STOPPED. THIS WAS DETECTED AFTER 41 MINUTES AND THE SYSTEM WAS AFTER THAT SET TO MANUAL GAS CONTROL WITH SEVOFLURANE VAPORIZER IN SLOT 1 SELECTED AND AGENT DELIVERY STARTED. THE PATIENT AWARENESS LEVEL INCREASED AND THIS WAS INDICATED BY BLOOD PRESSURE AND INCREASED RESPIRATORY RATE. NO REPORTED PSYCHOLOGICAL HARM. THE PATIENT HAS BEEN DISCHARGED. MANUFACTURER'S REFERENCE #: (B)(4).

    Patient problems: Awareness During Anesthesia

    MAUDE report 9226459 ↗
  • InjuryOct 23, 2019Unexpected Therapeutic Results; Unexpected Therapeutic Results

    MANUFACTURER'S REFERENCE #: (B)(4).

    Patient problems: Awareness During Anesthesia

    MAUDE report 9223969 ↗

Other Gas-Machine, Anesthesia devices

All Gas-Machine, Anesthesia devices →