Sonopet iQ 550025B312Recalls & reported problems

Stryker Corporation · 12cm iQ Apex 360 · Class U

All models of Sonopet iQ (16)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 07613327422412), received between Mar 4, 2021 and Aug 9, 2024 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Overheating of Device” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 2 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Overheating of Device2
  • Fracture1

Patient problems

  • Muscle Weakness/Atrophy2
  • Nerve Damage2
  • Abrasion1
  • Ambulation or Postural Difficulties1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 9, 2024Overheating of Device; Adverse Event Without Identified Device or Use Problem; Overheating of Device; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED POSTOPERATIVE, THE PATIENT EXPERIENCED RIGHT L5 AREA SENSORY LOSS, WEAKNESS OF FOOT TO TOE MUSCLES (FOOT MEDIAL ROTATION, DROP TOE), DUE TO DAMAGE CAUSED DURING USE OF THE SONOPET IQ TIP. IT WAS FURTHER REPORTED THAT THE PATIENT IS DOING WELL, AND SENSORY LOSS HAS RETURNED. IT WAS ALSO REPORTED THAT THE ORIGINAL PROCEDURE FORL4-5 LAMINECTOMY, RIGHT HERNIOTOMY, WAS COMPLETED SUCCESSFULLY, WITH NO MEDICAL INTERVENTION OR DELAYS.

    Patient problems: Muscle Weakness/Atrophy; Nerve Damage

    MAUDE report 19950804 ↗
  • InjuryAug 9, 2024Overheating of Device; Adverse Event Without Identified Device or Use Problem; Overheating of Device; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED POSTOPERATIVE, THE PATIENT EXPERIENCED SENSORY LOSS IN RIGHT L5 AREA, MILD MUSCLE WEAKNESS, DUE TO DAMAGE CAUSED DURING USE OF THE SONOPET IQ TIP. IT WAS FURTHER REPORTED THAT THE PATIENT WILL CONTINUE TO BE MONITORED. IT WAS ALSO REPORTED THAT THE ORIGINAL PROCEDURE FOR L3/4-L4 LAMINECTOMY, LEFT MASSIVE HERNIOTOMY, WAS COMPLETED SUCCESSFULLY, WITH NO MEDICAL INTERVENTION OR DELAYS.

    Patient problems: Ambulation or Postural Difficulties; Muscle Weakness/Atrophy; Nerve Damage

    MAUDE report 19950664 ↗
  • MalfunctionApr 16, 2024Fracture; Fracture

    THIS REPORT SUMMARIZES (B)(4) MALFUNCTION EVENT IN WHICH THE DEVICE OR CUTTING ACCESSORY FRACTURED. - (B)(4) EVENT HAD PATIENT INVOLVEMENT; NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19113504 ↗
  • InjuryMar 4, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE THERE WAS NO MALFUNCTION REPORTED WITH THE PRODUCT USED. IT WAS FURTHER REPORTED THAT THE PATIENTS REQUIRED MEDICAL INTERVENTION TO TREAT A CUT CAUSED BY UNINTENDED ACTIVATION OF THE PRODUCT. IT WAS ALSO REPORTED THAT A DELAY OF 30 MINUTES OCCURRED AS A RESULT OF THIS EVENT. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: Abrasion

    MAUDE report 11413222 ↗

Other Instrument, ultrasonic surgical devices

All Instrument, ultrasonic surgical devices →