The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613336179918), received between Jul 29, 2022 and Jul 29, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Low Test Results” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Low Test Results1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 29, 2022Low Test Results; Low Test Results

    THE INITIAL REPORTER RECEIVED QUESTIONABLE ELECSYS FT4 ASSAY, PROBNP G2 ELECSYS E2G V2, ELECSYS FERRITIN, FOLATE, ELECSYS TSH ASSAY AND ELECSYS VITAMIN B12 IMMUNOASSAY RESULTS FOR TWO PATIENT SAMPLES TESTED ON THE COBAS PRO SBL E 801. FOR SAMPLE 2063033611, THE INITIAL FT4 RESULT WAS REPORTED TO THE PHYSICIAN. THE PHYSICIAN DID NOT BELIEVE THE RESULT PROMPTING THE RERUN OF SEVERAL ASSAYS. DISCREPANT RESULTS WERE OBSERVED FOR FT4 AND PROBNP. ON (B)(6) 2022, SAMPLE 1'S INITIAL FT4 RESULT WAS 1.820 PMOL/L WITH A DATA FLAG. THE REPEAT RESULT WAS 40.9 PMOL/L. THE INITIAL PROBNP RESULT WAS <1 PMOL/L WITH A DATA FLAG. THE REPEAT RESULT WAS 67 PMOL/L. ON (B)(6) 2022, SAMPLE 2071221711'S INITIAL FERRITIN RESULT WAS 1.640 UG/L WITH A DATA FLAG. THE REPEAT RESULT WAS 114 UG/L. THE INITIAL FOLATE RESULT WAS <2.72 NMOL/L WITH A DATA FLAG. THE REPEAT RESULT WAS 45.100 NMOL/L. THE INITIAL TSH RESULT WAS <0.1 MIU/L WITH A DATA FLAG. THE REPEAT RESULT WAS 5.000 MIU/L. THE INITIAL VITAMIN B12 RESULT WAS <73.8 PMOL/L WITH A DATA FLAG. THE REPEAT RESULT WAS 366 PMOL/L. THE REPEAT RESULTS WERE DEEMED CORRECT. THE FT4 REAGENT LOT NUMBER IS 60647801 WITH AN EXPIRATION DATE OF 30-NOV-2022. THE PROBNP REAG

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15133328 ↗