The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07640119558783), received between Sep 8, 2025 and Sep 8, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Entrapment of Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Entrapment of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 8, 2025Entrapment of Device; Entrapment of Device

    THE PASSEO-18 PERIPHERAL BALLOON CATHETER WAS SELECTED FOR TREATMENT OF A MILDLY CALCIFIED LESION (50% STENOSIS DEGREE) IN A MILDLY TORTUOUS PART OF AN UNKNOWN VESSEL. AFTER BALLOON INFLATION WITHIN THE VESSEL, RESISTANCE WAS ENCOUNTERED WHILE ATTEMPTING TO WITHDRAW THE PASSEO-18 THROUGH THE FORTRESS DEVICE. THE SYSTEMS WERE REMOVED AS A UNIT, AND THE BALLOON WAS CUT AT THE PROXIMAL SHAFT TO REMOVE IT FROM THE SHEATH. AFTER RE-INSERTION OF THE FORTRESS, THE PROCEDURE WAS THEN CONTINUED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22991800 ↗