SMR Shoulder Finned Stem (REF 1304.15.170)Recalls & reported problems
Limacorporate SPA · Finned humeral stems - 80mm (Ti6Al4V) dia.17mm · Class 2 · Implant
All models of SMR Shoulder (65)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033390000918), received between May 30, 2025 and May 30, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem1
Patient problems
- Joint Laxity1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 30, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
SHOULDER REVISION SURGERY PERFORMED ON (B)(6) 2025, DUE TO LOOSENING. PATIENT UNDERWENT A PREVIOUS REVISION SURGERY WITH THE IMPLANT OF A REVERSE FOR FRACTURE (DATE UNKNOWN). THE FOLLOWING STEM WAS LOOSE AND WAS REMOVED: - SMR CEMENTLESS FINNED STEM (PART CODE 1304.15.170, LOT NUMBER 2114975, STERILIZATION 2100314). THE SURGEON PUT IN A LONG 16X150 REVISION STEM. THE OTHER COMPONENTS PREVIOUSLY IMPLANTED WERE LEFT IN SITU (EXCEPT THE HUMERAL STEM ABOVE MENTIONED, THE REVERSE TRAUMA BODY AND THE LINER): - SMR CONNECTOR SMALL R (PART CODE 1374.15.305, LOT NUMBER 2219451, STERILIZATION (B)(4)). - SMR METAL-BACK GLENOID SMALL R (PART CODE 1375.21.005, LOT NUMBER 2208559, STERILIZATION (B)(4)). - SMR ECCENT. GLENOSPHERE Ø 40MM (PART CODE 1376.09.041, LOT NUMBER 2214738, STERILIZATION (B)(4)). - SMR REVERSE FINNED HUMER. BODY (PART CODE 1352.15.050, LOT NUMBER 2010261, STERILIZATION (B)(4)). - SMR REVERSE LINER +3MM D.40MM (PART CODE 1365.50.815, LOT NUMBER 21AT106, STERILIZATION (B)(4)). PREVIOUS SURGERY TOOK PLACE ON (B)(6) 2022. THE EVENT HAPPENED IN THE UNITED STATES.
Patient problems: Joint Laxity
MAUDE report 22113640 ↗
FDA clearance and classification
Cleared through 510(k) K101263 on Jan 28, 2011 (decision: Substantially Equivalent). Submitted by Lima-Lto S.P.A. as “Lima-Lto Smr Shoulder System - Finned Humeral Stems, Lima-Lto Smr Shoulder System - Finned Humeral Bodies,”. The FDA review took 268 days. FDA record ↗
The FDA regulates product code HSD (prosthesis, shoulder, hemi-, humeral, metallic uncemented) under 21 CFR 888.3690 as a Class II device. 21 CFR 888.3690 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the SMR Shoulder Finned Stem
Has the SMR Shoulder Finned Stem been recalled?
No FDA recall record in our data names this exact device identifier (DI 08033390000918), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the SMR Shoulder Finned Stem?
The FDA's MAUDE database lists 1 adverse event report for this device, received on May 30, 2025. That report lists device problem “Patient Device Interaction Problem” (1); patient problem “Joint Laxity” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SMR Shoulder Finned Stem?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the SMR Shoulder Finned Stem FDA approved?
It was cleared through 510(k) K101263 on Jan 28, 2011. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the SMR Shoulder Finned Stem MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the SMR Shoulder Finned Stem, and is it still sold?
The FDA's device database lists Limacorporate SPA as the company responsible for it (brand SMR Shoulder, model Finned Stem). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented devices
- DJO SURGICAL 509-02-032Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED365 reports
- DELTA XTEND 130790036Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED169 reports
- DELTA XTEND 130770018Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED160 reports
- DJO SURGICAL 509-02-432Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED124 reports
- TRIGEN 71118200Smith & Nephew, Inc. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED123 reports
- DELTA XTEND 130738206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED114 reports
- COMPREHENSIVE SHOULDER SYSTEM 113633Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED2 recalls4 reports
- DELTA XTEND 130742206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED98 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page