PACIFIC XTREME PCU040250130Recalls & reported problems
Medtronic, Inc. · CATH PCU040250130 PCU US 04 00L250UL1300 · Class 2
All models of PACIFIC XTREME (25)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033477058405), received between Mar 5, 2019 and Mar 5, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
1 other recall cover devices cleared under the same FDA submission (K103464); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Remove1
Patient problems
- Patient Problem/Medical Problem1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 5, 2019Difficult to Remove; Difficult to Remove
IT WAS REPORTED THAT A PHYSICIAN WAS ATTEMPTING TO USE A PACIFIC XTREME BALLOON TO TREAT A LESION IN A PATIENT. A NON MEDTRONIC GUIDEWIRE (VIPER) AND INFLATION DEVICE (MERRIT) WAS USED. NO DAMAGE NOTED TO PACKAGING, I.E. SHELF CARTON, HOOP/TRAY, NO ISSUES NOTED WHEN REMOVING THE DEVICE FROM THE HOOP/TRAY, NO RESISTANCE ENCOUNTERED WHEN ADVANCING THE DEVICE, EXCESSIVE FORCE WAS USED DURING DELIVERY. IT WAS REPORTED THAT THE BALLOON ADVANCED TOO FAR INTO A COLLATERAL AND DOUBLED UP ON ITSELF. THEY COULD NOT GET IT TO UN DOUBLE AND GOT STUCK IN THE ILIAC. A SNARE RETRIEVER WAS USED. NO FURTHER PATIENT INJURY REPORTED, AND PATIENT OUTCOME WAS REPORTED TO BE GOOD.
Patient problems: Patient Problem/Medical Problem
MAUDE report 8389485 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K103464. One submission often covers many models, so check the product and lot details in each record.
- Z-3055-2020 · Aug 26, 2020 · TerminatedPacific Xtreme (PTCA Balloon Dilation Catheter)
Other Catheter, angioplasty, peripheral, transluminal devices
- Coyote™ ES H74939135152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal879 reports
- Coyote™ ES H74939135204010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal585 reports
- Coyote™ ES H74939135202010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal437 reports
- Coyote™ ES H74939135304010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal384 reports
- Coyote™ ES H74939135404010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal293 reports
- Coyote™ ES H74939134152010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal279 reports
- Coyote™ H74939185202210Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal200 reports
- Coyote™ ES H74939135254010Boston Scientific Corporation · Catheter, angioplasty, peripheral, transluminal127 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page