Pacific™ Plus PCP060200150Recalls & reported problems

Medtronic, Inc. · CATH PCP060200150 PLUS US D6L200UL1500 · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033477072883), received between Sep 8, 2025 and Sep 8, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Inflation Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Inflation Problem1
  • Leak/Splash1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 8, 2025Inflation Problem; Leak/Splash; Inflation Problem; Leak/Splash

    IT WAS REPORTED THAT DURING A PERIPHERAL ARTERY INTERVENTION INVOLVING THE CATHETER PACIFIC PLUS BALLOON, A PATIENT WAS TREATED FOR A CALCIFIED LESION IN THE RIGHT SUPERFICIAL FEMORAL ARTERY. THE TARGET LESION EXHIBITED 100% STENOSIS, MEASURED 150 MM IN LENGTH, AND HAD A MODERATE DEGREE OF CALCIFICATION. INFLATION DIFFICULTIES WERE ENCOUNTERED WITH THE REPORTED CATHETER DEVICE, AND A LEAK WAS NOTED ON THE SHAFT. THE DEVICE FUNCTIONED DURING VESSEL PREPARATION BUT WOULD NOT INFLATE TO POST-DILATE AFTER STENT PLACEMENT (MEDTRONIC EVERFLEX PRB35-06-200-120 AND MEDTRONIC EVERFLEX EVD35-06-150-120). THE VESSEL WAS PRE-DILATED USING THE SAME DEVICE AND POST-DILATED WITH A MEDTRONIC ADMIRAL XTREME 6 X 250 X 130 CM AFTER THE REPORTED DEVICE FAILED TO INFLATE. THE DEVICE WAS SAFELY REMOVED FROM THE PATIENT, AND THE PROCEDURE WAS COMPLETED USING A NEW DEVICE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. THERE WAS NO DAMAGE NOTED TO THE STENTS. THE PHYSICIAN EXPERIENCE A LOT OF RESISTANCE THROUGHOUT THE PROCEDURE PARTICULARLY WHEN WITHDRAWING THE BALLOON FROM THE PATIENT INTO THE SHEATH.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22991589 ↗

Other Catheter, angioplasty, peripheral, transluminal devices