Pacific™ Plus PCP040200200Recalls & reported problems

Medtronic, Inc. · CATH PCP040200200 PLUS US D4L200UL2000 · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033477075228), received between Jul 9, 2025 and Jul 9, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Defective Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Component1
  • Difficult to Advance1
  • Difficult to Remove1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 9, 2025Difficult to Remove; Defective Component; Difficult to Advance; Difficult to Remove; Defective Component; Difficult to Advance

    IT WAS REPORTED THAT DURING A PROCEDURE INVOLVING THE CATHETER PACIFIC PLUS, LOSS OF WIRE ACCESS OCCURRED WHEN THE GUIDEWIRE BECAME STUCK IN THE BALLOON WHILE TREATING A MODERATE, CALCIFIED LESION IN THE MID LEFT SUPERFICIAL FEMORAL ARTERY. HAD TO ABORT BALLOONING, AND ACCESS ACROSS THE LESION HAD TO BE RE-ESTABLISHED. A NEW PACIFIC PLUS PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY CATHETER (4MMX200MMX200MM) WAS USED TO COMPLETE THE PROCEDURE. THE RADIOPAQUE BALLOON MARKERS WERE REPORTEDLY MARKED INCORRECTLY, WITH DOUBLE MIDDLE MARKERS IN THE WRONG POSITION. TRACKING DIFFICULTY WAS NOTED DURING INITIAL ADVANCEMENT DUE TO AN ANCILLARY DEVICE, AND AFTER INFLATION, THERE WAS DIFFICULTY REMOVING THE BALLOON BECAUSE THE 0.018 GUIDEWIRE WAS STUCK INSIDE. THE BALLOON WAS SUCCESSFULLY REMOVED IN TANDEM WITHOUT INJURY OR INTERVENTION, AND THERE WAS NO VESSEL DAMAGE. THE INSTRUCTIONS FOR USE WERE FOLLOWED WITHOUT ISSUE, AND THE VESSEL WAS POST-DILATED WITH 50/50 CONTRAST AS THE INFLATION FLUID. NO ABNORMALITIES WERE REPORTED IN RELATION TO ANATOMY, AND THE DEGREE OF TORTUOSITY WAS MINIMAL. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22459872 ↗

Other Catheter, angioplasty, peripheral, transluminal devices

All Catheter, angioplasty, peripheral, transluminal devices →