First Choice UHP7594Recalls & reported problems

Creagh Medical Limited · Class 2

All models of First Choice (9)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08570590020075), received between Sep 23, 2024 and Sep 23, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1
  • Material Separation1
  • Off-Label Use1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 23, 2024Fracture; Off-Label Use; Material Separation; Fracture; Off-Label Use; Material Separation

    THE PATIENT PRESENT FOR A FISTALGRAM AND ANGIOPLASTY PROCEDURE. IT WAS DETERMINED THE CEPHALIC ARCH WAS APPROXIMATELY 80% STENOSED. THE HIGH PRESSURE BALLOON INFLATIONS WERE PERFORMED. MODERATE WASTE NOTED, FOLLOWED BY FULL EFFACEMENT AT 22ATM. THE BALLOON WAS DEFLATED AND EASILY REMOVED. THE STENOSIS WAS REEVALUATED WITH CONTRAST INJECTION. SIGNIFICANT STENOSIS PRESENCE WAS IDENTIFIED AND STENT PLACEMENT WAS PERFORMED. THE BALLOON WAS ADVANCED OVER WIRE AND INFLATIONS PERFORMED. THE BALLOON WAS USED TO FULLY EXPAND THE STENT AND SET IN PLACE AGAINST THE VESSEL WALL. THE INTENTION WAS TO INFLATE THE BALLOON TO 20ATM. HOWEVER, THE BALLOON RUPTURED AT 16ATM. THE BALLOON WAS DIFFICULT TO REMOVE AS IT APPEARED TO BE STUCK TO NEWLY PLACED STENT. WITH MUCH DIFFICULTY BALLOON WAS ABLE TO BE PULLED FOLLOWED BY SHEATH REMOVAL. EXAMINATION OF THE BROKEN BALLOON WAS THEN PERFORMED. THE BALLOON WAS DETERMINED TO HAVE RUPTURED TRANSVERSELY WITH HALF OUT OF THE BODY AND OTHER HALF REMAINING INSIDE. THE REMAINING BALLOON WAS ULTIMATELY ABLE TO BE REMOVED OVER THE WIRE WITH FORCE. FOLLOWING BALLOON REMOVAL, THE GUIDEWIRE WAS ABLE TO MOVE FREELY. UNDER HIGH MAGNIFICATION AREA OF SHEATH WAS PRESENT

    Patient problems: Foreign Body In Patient

    MAUDE report 20285557 ↗

Other Catheter, Angioplasty, Peripheral, Transluminal devices

All Catheter, Angioplasty, Peripheral, Transluminal devices →