Boston Scientific Corporation · Drainage Catheter System · Class 2 · Implant

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729300670), received between Aug 24, 2021 and Dec 19, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Difficult to Remove” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Remove2
  • Adverse Event Without Identified Device or Use Problem1
  • Defective Device1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 19, 2025Material Deformation; Adverse Event Without Identified Device or Use Problem; Material Deformation; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT STENT DAMAGE OCCURRED. A 7.3 FLEXIMA ALL PURPOSE DRAINAGE WAS SELECTED FOR USE. DURING THE PROCEDURE, THE STENT WAS DAMAGED DURING ATTEMPTED PLACEMENT OVER THE GUIDEWIRE. A TEAR OCCURRED ON THE DISTAL SIDE OF THE STENT, ALLOWING THE GUIDEWIRE TO EXIT THROUGH THE SIDE OF THE STENT. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE OF THE SAME MODEL WITHOUT ISSUE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23853477 ↗
  • MalfunctionOct 21, 2024Difficult to Remove; Difficult to Remove

    REPORTABLE BASED ON THE DEVICE ANALYSIS COMPLETED ON 25SEP2024. IT WAS REPORTED THAT THE STENT WAS DETACHED IN THE PROXIMAL SECTION. AN APDLTL/7.3 FLEXIMA ALL-PURPOSE DRAINAGE WAS SELECTED FOR USE. DURING THE PROCEDURE, THERE WAS RESISTANCE DURING STENT DEPLOYMENT, AND THE SHEATH COULD NOT BE ADVANCED. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED. HOWEVER, PRODUCT INVESTIGATION REVEALED THAT STENT ALSO WAS DETACHED AT PROXIMAL SECTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20495348 ↗
  • MalfunctionAug 24, 2021Difficult to Remove; Defective Device; Difficult to Remove; Defective Device

    IT WAS REPORTED THE GUIDEWIRE WAS DIFFICULT TO REMOVE. A 7.3 FLEXIMA APDL WAS SELECTED FOR USE IN A LIVER ABSCESS DRAINAGE PROCEDURE. DURING THE PROCEDURE, THE DEVICE WAS INSERTED INTO THE ABSCESS OVER A GUIDEWIRE. AN ATTEMPT WAS MADE TO REMOVE THE METAL STYLET, BUT WAS UNSUCCESSFUL. SUBSEQUENTLY, ANOTHER ATTEMPT WAS MADE TO REMOVE THE DEVICE, LEAVING THE GUIDE WIRE, BUT WAS UNSUCCESSFUL, SO EVERYTHING WAS REMOVED FROM THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER DEVICE WITH NO COMPLICATIONS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12360806 ↗

Other TUBE, DRAINAGE, SUPRAPUBIC devices

All TUBE, DRAINAGE, SUPRAPUBIC devices →