Flexima™ APDL M001271310Recalls & reported problems

Boston Scientific Corporation · Drainage Catheter System · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08714729323082), received between Oct 29, 2025 and Nov 4, 2025 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Defective Device1
  • Deformation Due to Compressive Stress1
  • Difficult to Insert1
  • Obstruction of Flow1
  • Positioning Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • Pain1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 4, 2025Obstruction of Flow; Deformation Due to Compressive Stress; Positioning Problem; Obstruction of Flow; Deformation Due to Compressive Stress; Positioning Problem

    IT WAS REPORTED THAT THE DRAINAGE CATHETER WAS DIFFICULT TO REMOVE. A 6 FRENCH FLEXIMA APDL WAS SELECTED FOR USE TO DRAIN A BILIARY ABSCESS. THE DRAINAGE CATHETER WAS INSERTED INTO THE PATIENT, BUT THE DRAIN COULD NOT BE RELEASED. THE PLASTIC CANNULA FOLDED BACK ON ITSELF LIKE AN ACCORDION WHEN THE INTERNAL METAL COMPONENT WAS PULLED. THE DRAIN, THEREFORE, COULD NOT BE USED AS THE LUMEN WAS COVERED BY THE INTERNAL METAL PART. REMOVAL OF THE DRAIN WAS DIFFICULT BECAUSE OF THE ACCORDION LIKE DAMAGE, AND RESULTED IN PAIN DURING REMOVAL. A NEW DRAIN WAS SUCCESSFULLY INSERTED. THERE WERE NO FURTHER PATIENT COMPLICATIONS AS A RESULT OF THE EVENT.

    Patient problems: Pain

    MAUDE report 23468127 ↗
  • MalfunctionOct 29, 2025Difficult to Insert; Defective Device; Adverse Event Without Identified Device or Use Problem; Difficult to Insert; Defective Device; Adverse Event Without Identified Device or Use Problem

    REPORTABLE BASED ON DEVICE ANALYSIS COMPLETED ON 15OCT2025. IT WAS REPORTED THAT THE DEVICE DID NOT FUNCTION AS EXPECTED. A FLEXIMA ALL PURPOSE DRAINAGE CATHETER WAS SELECTED FOR USE IN A PROCEDURE. DURING THE PROCEDURE, THE FLEXIMA ALL PURPOSE DRAINAGE CATHETER WAS DAMAGED AND DID NOT FUNCTION AS EXPECTED. A DIFFERENT DEVICE OF THE SAME MODEL WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT. HOWEVER, DEVICE ANALYSIS REVEALED THE DEVICE MATERIAL SEPARATED AND DETACHED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23417252 ↗