Flexima™ Nasobiliary Catheter M00540130Recalls & reported problems

Boston Scientific Corporation · Nasobiliary Catheter · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 08714729337393), received between Jul 14, 2021 and Sep 3, 2026 — classified as 2 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Material Split, Cut or Torn2
  • Adverse Event Without Identified Device or Use Problem1
  • Detachment of Device or Device Component1
  • Leak/Splash1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Fever1
  • Foreign Body In Patient1
  • Insufficient Information1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjurySep 3, 2026Leak/Splash; Material Split, Cut or Torn

    It was reported to Boston Scientific Corporation that a Flexima Nasobiliary Catheter was used for dilation of the intra and extrahepatic bile ducts with stone removal in the descending duodenum during an Endoscopic Retrograde Cholangiopancreatography (ERCP), Endoscopic Nasobiliary Drainage (ENBD), and biliary stent placement procedure performed on (b)(6) 2026. Following the procedure, the patient's jaundice worsened. Subsequent Computed tomography imaging demonstrated dislodgement of the ENBD drainage tube and prolapse of the biliary stent.On (b)(6) 2026, the patient underwent a repeat ERCP with ENBD placement and biliary stent replacement; however, no clinical improvement was observed. The originally placed nasobiliary drainage tube was removed using foreign body forceps. A follow-up CT scan performed on (b)(6) 2026, assessed the ENBD and biliary stent placement. Further CT imaging performed thereafter was reviewed with the Radiology Department, which confirmed that the drainage tube remained in situ, with the distal tip of the ENBD located in the lower common bile duct. On the same day, the attending physician performed a bedside saline flush of the ENBD tube and identified a cra

    Patient problems: Fever; Insufficient Information

    MAUDE report 50600072 ↗
  • InjuryJun 25, 2026Break; Material Split, Cut or Torn

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A FLEXIMA NASOBILIARY CATHETER WAS INTENDED TO BE IMPLANTED IN THE COMMON BILE DUCT TO TREAT JAUNDICE AND LOWER ABDOMINAL PAIN DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE WITH STONE REMOVAL PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE TIP OF THE NASOBILIARY DRAINAGE CATHETER FRACTURED AFTER IT HAD BEEN INSERTED INTO THE PATIENT. THE FRACTURED SEGMENT REMAINED IN THE PATIENT'S COMMON BILE DUCT AND WAS DIFFICULT TO RETRIEVE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULTS OF THIS EVENT AND THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE STABLE.

    Patient problems: Foreign Body In Patient

    MAUDE report 25630754 ↗
  • MalfunctionMay 18, 2026Break

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A FLEXIMA NASOBILIARY CATHETER WAS USED IN THE DUODENAL PAPILLA TO TREAT COMMON BILE DUCT STONES DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE PERFORMED ON (B)(6) 2026. DURING PREPARATION, THE TIP WAS CRACKED. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. NOTE: A PHOTO OF THE DEVICE WAS PROVIDED WHEREIN A TORN/SPLIT IS SHOWN AT THE TIP OF THE STENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25211218 ↗
  • MalfunctionDec 10, 2025Break; Adverse Event Without Identified Device or Use Problem; Break; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NASOBILIARY CATHETER WAS TO BE IMPLANTED TO TREAT A BILE DUCT TUMOR IN THE GALLSTONES DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) WITH ENDOSCOPIC SPHINCTEROTOMY (EST) INVOLVING THE EXTRAHEPATIC BILE DUCT (EHBD) PROCEDURE PERFORMED ON (B)(6), 2025. DURING PREPARATION PRIOR TO PROCEDURE THE FRONT END WAS FRACTURED WHEN IT WAS UNPACKED. ANOTHER NASOBILIARY CATHETER WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE STABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23771629 ↗
  • MalfunctionJul 14, 2021Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A FLEXIMA NASOBILIARY CATHETER WAS USED DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE IN THE CALCULUS OF BILE DUCT PERFORMED ON (B)(6), 2021. DURING PREPARATION, IT WAS FOUND THAT THE PIG TAIL END WAS DETACHED AND COULD NOT BE USED. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH ANOTHER FLEXIMA NASOBILIARY CATHETER. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE STABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12165400 ↗

Other CATHETER, BILIARY, DIAGNOSTIC devices

All CATHETER, BILIARY, DIAGNOSTIC devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page