Graspit M0063204010Recalls & reported problems

Boston Scientific Corporation · Nitinol Stone Retrieval Forceps · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08714729341758), received between Mar 23, 2020 and Mar 2, 2021 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Detachment of Device or Device Component2
  • Material Split, Cut or Torn1

Patient problems

  • Insufficient Information1
  • Perforation1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 2, 2021Detachment of Device or Device Component; Material Split, Cut or Torn; Detachment of Device or Device Component; Material Split, Cut or Torn

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A GRASPIT NITINOL STONE RETRIEVAL FORCEPS WAS USED IN THE URETER DURING A FLEXIBLE URETERORENOSCOPY PROCEDURE PERFORMED ON (B)(6) 2020. DURING THE PROCEDURE, THE FORCEPS OF THE GRASPIT BROKE OFF INSIDE THE FLEXIBLE URETEROSCOPE. ADDITIONALLY, THE SHEATH AT THE DISTAL END SNAPPED OFF. BOSTON SCIENTIFIC HAS BEEN UNABLE TO OBTAIN ADDITIONAL INFORMATION REGARDING THE EVENT TO DATE, DESPITE GOOD FAITH EFFORTS. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Insufficient Information

    MAUDE report 11398697 ↗
  • InjuryMar 23, 2020Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A GRASPIT NITINOL STONE RETRIEVAL FORCEPS WAS USED IN THE URETER DURING A LITHOTRIPSY PROCEDURE FOR REMOVAL OF RENAL STONES PERFORMED ON (B)(6) 2020. ACCORDING TO THE COMPLAINANT, WHEN TRYING TO REMOVE A LASERED STONE DURING THE PROCEDURE THE FORCEPS BROKE AT THE TIP WERE THE FORCEPS OPEN. THE FRACTURED FORCEPS WAS REMOVED FROM THE PATIENT WITH ANOTHER GRASPING FORCEPS. HOWEVER, THE URETER WAS PUNCTURED FROM MULTIPLE ATTEMPTS TO REMOVE THE BROKEN FORCEPS. AN ATTEMPT TO INSERT A NEPHROSTOMY FAILED, AND BILATERAL RETROPERITONEAL DRAINS WERE INSERTED INSTEAD. BOSTON SCIENTIFIC HAS BEEN UNABLE TO OBTAIN ADDITIONAL INFORMATION REGARDING THE EVENT TO DATE, DESPITE GOOD FAITH EFFORTS. ADDITIONAL INFORMATION RECEIVED ON APRIL 1, 2020. THE PATIENT WAS REPORTED TO BE A CHILD, AND THE PATIENT'S CURRENT CONDITION WAS REPORTED TO BE OKAY.

    Patient problems: Perforation

    MAUDE report 9865234 ↗

FDA clearance and classification

The FDA regulates product code FFL (dislodger, stone, basket, ureteral, metal) under 21 CFR 876.4680 as a Class II device. 21 CFR 876.4680 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Graspit M0063204010

Has the Graspit M0063204010 been recalled?

No FDA recall record in our data names this exact device identifier (DI 08714729341758), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Graspit M0063204010?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 23, 2020 and Mar 2, 2021. In those reports, the most common specific device problems are “Detachment of Device or Device Component” (2) and “Material Split, Cut or Torn” (1); the most common patient problem is “Perforation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Graspit M0063204010?

None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Graspit M0063204010 FDA approved?

Devices of this type (product code FFL) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Boston Scientific Corporation.

Who makes the Graspit M0063204010, and is it still sold?

The FDA's device database lists Boston Scientific Corporation as the company responsible for it (brand Graspit, model M0063204010). Its record shows it as no longer in commercial distribution.