WallFlex™ Biliary M00570500Recalls & reported problems

Boston Scientific Corporation · WALLFLEX BILIARY RX COVERED 8X60 · Class 2 · Implant

All models of WallFlex Biliary (23)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729764885), received between Aug 14, 2018 and Oct 2, 2024 — classified as 3 injuries.

The most frequently reported specific device problem is “Positioning Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Problem2
  • Activation Failure1
  • Difficult to Remove1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 2, 2024Activation Failure; Activation Failure

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A WALLFLEX BILIARY RX COVERED STENT WAS TO BE IMPLANTED TO TREAT A MALIGNANT BILIARY STENOSIS DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE PERFORMED ON (B)(6) 2024. DURING THE PROCEDURE, THE STENT WOULD NOT FULLY EXPAND. THE STENT WAS REMOVED FROM THE PATIENT WITH A FOREIGN BODY DEVICE, AND ANOTHER WALLFLEX BILIARY STENT WAS PLACED TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT CONDITION FOLLOWING THE PROCEDURE WAS REPORTED TO BE STABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20353678 ↗
  • InjuryJan 11, 2022Positioning Problem; Positioning Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION ON (B)(6) 2021 THAT A WALLFLEX BILIARY RX COVERED STENT WAS TO BE IMPLANTED TO TREAT A BENIGN STENOSIS IN THE AMPULLA DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) WITH STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2021. REPORTEDLY, THE PATIENT'S ANATOMY WAS NOT TORTUOUS AND WAS NOT DILATED PRIOR TO STENT PLACEMENT. DURING THE PROCEDURE, THE STENT WAS ABLE TO BE DEPLOYED; HOWEVER, IT WAS NOTED THAT THE STENT WAS INCORRECTLY PLACED NEAR THE HEPATIC DUCTS. THE STENT WAS REMOVED WITH BIOPSY FORCEPS AND ANOTHER WALLFLEX BILIARY STENT WAS IMPLANTED TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT. THE PATIENT CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE STABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13224789 ↗
  • InjuryAug 14, 2018Difficult to Remove; Use of Device Problem; Positioning Problem; Difficult to Remove; Use of Device Problem; Positioning Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION ON (B)(6) 2018 THAT A WALLFLEX BILIARY RX COVERED STENT WAS IMPLANTED TO TREAT A STENOSIS IN THE MIDDLE AND DISTAL THIRD PART OF COMMON BILE DUCT WHICH WAS CAUSED BY INFILTRATION SECONDARY TO GASTRIC CANCER DURING A PERCUTANEOUS BILIARY STENT PLACEMENT UNDER FLUOROSCOPIC GUIDANCE PROCEDURE PERFORMED ON (B)(6) 2018. REPORTEDLY, THE PATIENT HAD GASTRECTOMY FOR GASTRIC CANCER. THE PATIENT'S ANATOMY WAS NOT TORTUOUS AND WAS DILATED PRIOR TO STENT PLACEMENT. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THE STENT WAS ABLE TO DE DEPLOYED, HOWEVER, ONE OF THE STENT WIRE EDGES GOT STUCK IN THE CATHETER WHEN THE DELIVERY SYSTEM WAS ATTEMPTED TO BE REMOVED. SUBSEQUENT TO REMOVAL OF THE DELIVERY SYSTEM, A CEPHALIC MIGRATION OF THE STENT OCCURRED. THE STENT WAS LEFT IMPLANTED INSIDE THE PATIENT AND A PERCUTANEOUS BILIARY DRAINAGE CATHETER WAS PLACED FOR BILIARY DRAINAGE. REPORTEDLY, THE PROCEDURE WILL BE CONTINUED ON AN UNKNOWN DATE TO IMPLANT A SECOND BSC STENT. THERE WERE NO SERIOUS INJURIES AND NO ADVERSE EFFECTS FOR THE PATIENT. NOTE: ACCORDING TO THE COMPLAINANT, THE PATIENT HAD A HISTORY OF GASTRECTOMY FOR GASTRIC CANCER WHICH PREVEN

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7780892 ↗

Other CATHETER, BILIARY, DIAGNOSTIC devices

All CATHETER, BILIARY, DIAGNOSTIC devices →