Skip to content

Charger™ H74939206050410Recalls & reported problems

Boston Scientific Corporation · PTA Balloon Dilatation Catheter · Class 2

All models of Charger (49)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729804246), received between Apr 8, 2022 and Nov 24, 2024 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Entrapment of Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Entrapment of Device1
  • Failure to Deflate1
  • Material Deformation1
  • Material Rupture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Perforation of Vessels1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 24, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT BALLOON RUPTURED. A 5.0 X40, 135CM CHARGER BALLOON CATHETER WAS ADVANCED FOR DILATION. DURING INFLATION, THE BALLOON RUPTURED BEFORE REACHING THE RATED PRESSURE. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20768088 ↗
  • InjuryOct 3, 2024Failure to Deflate; Failure to Deflate

    IT WAS REPORTED THAT THE BALLOON FAILED TO DEFLATE. THIS 5.0 X 40, 135CM CHARGER BALLOON AND NON-BOSTON SCIENTIFIC 5F INTRODUCER WAS SELECTED FOR TREATMENT OF SPINAL MUSCLE ATROPHY OF THE CELIAC TRUCK. THE PROCEDURE WENT AS EXPECTED; HOWEVER, DURING REMOVAL THE BALLOON WAS NOT ABLE TO BE DEFLATED. THE PHYSICIAN WAS UNSUCCESSFUL AT ATTEMPTING TO USE A "DILATOR HANDLE" TO REMOVE. AT LAST, THEY WITHDREW THE BALLOON TOGETHER WITH THE INTRODUCER. THIS CAUSED A BIGGER "ENTRANCE HOLE" THAN NORMAL AND TOOK ADDITIONAL TIME AND SUTURES TO CLOSE THE ACCESS POINT. THE PATIENT WAS REPORTED AS FULLY RECOVERED.

    Patient problems: Perforation of Vessels

    MAUDE report 20361430 ↗
  • MalfunctionApr 8, 2022Entrapment of Device; Material Deformation; Entrapment of Device; Material Deformation

    IT WAS REPORTED THAT CATHETER ENTRAPMENT OCCURRED. THE 80% STENOSED TARGET LESION WAS LOCATED IN THE MILDLY TORTUOUS AND MILDLY CALCIFIED SUPERFICIAL FEMORAL ARTERY. A 5.0 X40, 135CM CHARGER BALLOON CATHETER WAS ADVANCED FOR DILATATION. AFTER INFLATION, THE DEVICE WAS ATTEMPTED TO BE REMOVED OVER THE GUIDE WIRE. HOWEVER, THE WIRE WAS LOCKED ONTO THE DEVICE. BOTH THE BALLOON AND WIRE WERE REMOVED TOGETHER AS A UNIT. FURTHERMORE, A KINK NEAR THE HUB WAS NOTED. THE PROCEDURE WAS COMPLETED WITH NO PATIENT COMPLICATIONS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14052972 ↗

Other Catheter, angioplasty, peripheral, transluminal devices

All Catheter, angioplasty, peripheral, transluminal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page