NephroMax Kit M0062101620Recalls & reported problems

Boston Scientific Corporation · High Pressure Nephrostomy Balloon Catheter Kit · Class U

All models of NephroMax Kit (4)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 08714729834526), received between Jun 4, 2019 and Aug 26, 2025 — classified as 2 injuries, 12 malfunctions.

The most frequently reported specific device problem is “Burst Container or Vessel” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Burst Container or Vessel5
  • Device Contamination with Chemical or Other Material4
  • Material Twisted/Bent2
  • Adverse Event Without Identified Device or Use Problem1
  • Defective Device1
  • Detachment of Device or Device Component1
  • Material Deformation1
  • Peeled/Delaminated1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • No Consequences Or Impact To Patient4
  • Hemorrhage/Blood Loss/Bleeding2
  • Insufficient Information2
  • No Known Impact Or Consequence To Patient2

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 26, 2025Material Twisted/Bent; Material Twisted/Bent

    IT WAS REPORTED THAT A NEPHROMAX NEPHROSTOMY BALLOON CATHETER DEVICE WAS USED DURING A PROCEDURE. DURING THE PROCEDURE, THE TIP OF THE DEVICE WAS BENT AND SQUASHED WHICH COULD CAUSE DAMAGE TO THE KIDNEY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22893312 ↗
  • MalfunctionJan 8, 2025Burst Container or Vessel; Burst Container or Vessel

    IT WAS REPORTED THAT A NEPHROMAX NEPHROSTOMY BALLOON CATHETER DEVICE WAS USED DURING A PERCUTANEOUS NEPHROLITHOTOMY (PCNL) PROCEDURE. DURING THE PROCEDURE, THE PHYSICIAN WAS TRYING TO INFLATE THE BALLOON AND NOTICED UNDER FLOURO THAT THE BALLOON WAS NOT TAKING SHAPE. REPORTEDLY, UPON DEFLATING AND PULLING OUT THE BALLOON IT BURST, AND THE PRESSURE WAS AT 20 ATMOSPHERES (ATM). THEY TRIED RE-INFLATING THE BALLOON, BUT IT WAS NOT POSSIBLE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE WITH NO PATIENT COMPLICATIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21107952 ↗
  • MalfunctionDec 20, 2022Defective Device; Detachment of Device or Device Component; Defective Device; Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX BALLOON WAS USED IN THE KIDNEY DURING A PERCUTANEOUS NEPHROLITHOTOMY (PCNL) PROCEDURE ON DECEMBER 1, 2022. DURING THE PROCEDURE, THE RENAL SHEATH WAS ADVANCED AND IT WAS NOTICED THAT THE RADIOPAQUE MARKER WAS DAMAGED AND BENT. UNDER EXAMINATION, THE RADIOPAQUE MARKER FELL OFF THE SHEATH AND WAS REMOVED. REPORTEDLY, SOME BLEEDING OCCURRED DURING DEFLATION OF THE BALLOON; HOWEVER, THE PROCEDURE WAS COMPLETED AT THIS TIME. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. ADDITIONAL INFORMATION RECEIVED ON DECEMBER 19, 2022 THAT THE BALLOON WAS NOT RUPTURED AND DAMAGED. THE BLEEDING WAS CONTROLLED BY THE PHYSICIAN'S EXPERTISE AND THE PATIENT WAS DOING WELL. REPORTEDLY, THE PHYSICIAN COULD NOT USE FLURO WHEN ADVANCING SO ADVANCEMENT OF THE SHEATH WAS DONE UNDER DIRECT VISUALIZATION. THE CUSTOMER STATED THAT NO PIECES OF THE BALLOON DETACHED INSIDE THE PATIENT.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 16013444 ↗
  • InjuryJun 29, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX NEPHROSTOMY BALLOON CATHETER WAS USED IN THE RIGHT KIDNEY DURING A PERCUTANEOUS NEPHROLITHONOMY (PCNL) PROCEDURE PERFORMED ON (B)(6) 2022. DURING THE PROCEDURE, THE PHYSICIAN HAD DILATED PERCUTANEOUSLY AS USUAL; HOWEVER, WHEN THE PHYSICIAN ADVANCED THE SHEATH AND BEGAN TO DEFLATE THE BALLOON, BLEEDING WAS OBSERVED FROM THE PATIENT. THE BLEEDING WAS CONTROLLED, BUT ANESTHESIA BEGAN WORKING UP THE PATIENT. THE PROCEDURE WAS NOT COMPLETED DUE TO THIS EVENT. THERE WAS NO REPORTED DEFICIENCY OR MALFUNCTION OF THE NEPHROMAX BALLOON AND IT WAS NOT CLEAR WHETHER THE BALLOON CONTRIBUTED TO THE BLEEDING. THE PATIENT'S CURRENT CONDITION WAS REPORTED TO BE WELL.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 14851575 ↗
  • MalfunctionMar 11, 2021Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material

    NOTE: THIS REPORT PERTAINS TO ONE OF TWO NEPHROMAX BALLOON CATHETER KITS USED IN THE SAME PATIENT AND PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT TWO NEPHROMAX BALLOON CATHETER KITS WERE USED DURING A PROCEDURE PERFORMED ON AN UNKNOWN DATE. IT WAS REPORTED THAT WHILE UNPACKING OF THE DEVICE DURING PREPARATION, IT WAS NOTICED THAT BOTH DEVICES LOOK DARK AND DIRTY. A PHOTO SUBMITTED BY THE CUSTOMER CONFIRMED THE FOREIGN MATERIAL PRESENT ON THE DEVICE. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX BALLOON CATHETER KIT. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. BOSTON SCIENTIFIC HAS BEEN UNABLE TO OBTAIN ADDITIONAL INFORMATION REGARDING THE EVENT TO DATE, DESPITE GOOD FAITH EFFORTS.

    Patient problems: Insufficient Information

    MAUDE report 11464745 ↗
  • MalfunctionMar 11, 2021Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material

    NOTE: THIS REPORT PERTAINS TO ONE OF TWO NEPHROMAX BALLOON CATHETER KITS USED IN THE SAME PATIENT AND PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT TWO NEPHROMAX BALLOON CATHETER KITS WERE USED DURING A PROCEDURE PERFORMED ON AN UNKNOWN DATE. IT WAS REPORTED THAT WHILE UNPACKING OF THE DEVICE DURING PREPARATION, IT WAS NOTICED THAT BOTH DEVICES LOOK DARK AND DIRTY. A PHOTO SUBMITTED BY THE CUSTOMER CONFIRMED THE FOREIGN MATERIAL PRESENT ON THE DEVICE. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX BALLOON CATHETER KIT. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. BOSTON SCIENTIFIC HAS BEEN UNABLE TO OBTAIN ADDITIONAL INFORMATION REGARDING THE EVENT TO DATE, DESPITE GOOD FAITH EFFORTS.

    Patient problems: Insufficient Information

    MAUDE report 11463603 ↗
  • MalfunctionFeb 4, 2021Burst Container or Vessel; Burst Container or Vessel

    NOTE: THIS REPORT PERTAINS TO ONE OF TWO NEPHROMAX DILATATION BALLOON CATHETERS USED IN THE SAME PATIENT AND PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT TWO NEPHROMAX DILATATION BALLOON CATHETERS WERE USED IN THE NEPHROSTOMY TRACT DURING A PROCEDURE PERFORMED ON AN UNKNOWN DATE. ACCORDING TO THE COMPLAINANT, DURING PREPARATION, IT WAS NOTED THAT BOTH BALLOONS BURST. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX DILATATION BALLOON CATHETER. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11278114 ↗
  • MalfunctionFeb 4, 2021Burst Container or Vessel; Burst Container or Vessel

    NOTE: THIS REPORT PERTAINS TO ONE OF TWO NEPHROMAX DILATATION BALLOON CATHETERS USED IN THE SAME PATIENT AND PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT TWO NEPHROMAX DILATATION BALLOON CATHETERS WERE USED IN THE NEPHROSTOMY TRACT DURING A PROCEDURE PERFORMED ON AN UNKNOWN DATE. ACCORDING TO THE COMPLAINANT, DURING PREPARATION, IT WAS NOTED THAT BOTH BALLOONS BURST. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX DILATATION BALLOON CATHETER. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11278100 ↗
  • MalfunctionJan 14, 2021Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX BALLOON CATHETER WAS USED IN THE KIDNEY DURING A PERCUTANEOUS NEPHROLITHOTOMY (PCNL) PROCEDURE PERFORMED ON (B)(6) 2020. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, A BLACK RESIDUE WAS NOTICED ON THE BALLOON UPON OPENING THE PACKAGE. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX BALLOON CATHETER. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE STABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 11171301 ↗
  • InjuryAug 18, 2020Peeled/Delaminated; Material Deformation; Peeled/Delaminated; Material Deformation

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX BALLOON CATHETER KIT WAS USED IN THE KIDNEY DURING A PERCUTANEOUS NEPHROLITHOTOMY (PCNL) PROCEDURE PERFORMED ON (B)(6) 2020. ACCORDING TO THE COMPLAINANT, AT THE END OF THE CASE, IT WAS NOTED THAT A SMALL PIECE OF THE RENAL SHEATH DETACHED INSIDE THE PATIENT. REPORTEDLY, THE DETACHED PIECE WAS RETRIEVED USING A BASKET. ADDITIONALLY, THE CLEAR RENAL SHEATH WAS NOTED BENT DUE TO TORQUING AND PATIENT ANATOMY. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX BALLOON CATHETER KIT. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE STABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10419999 ↗
  • MalfunctionDec 11, 2019Material Twisted/Bent; Material Twisted/Bent

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX BALLOON CATHETER WAS USED IN THE KIDNEY DURING A KIDNEY STONE REMOVAL PERCUTANEOUS NEPHROLITHOTOMY (PCNL) PROCEDURE PERFORMED ON (B)(6) 2019. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, IT WAS NOTED THAT THE DISTAL TIP OF THE CATHETER KINKED WHILE INSERTING INTO THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX BALLOON CATHETER. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE GOOD.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9450418 ↗
  • MalfunctionOct 17, 2019Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX DILATATION BALLOON CATHETER KIT WAS UNPACKED FOR A PERCUTANEOUS NEPHROLITHOTOMY (PCNL) PROCEDURE ON (B)(6) 2019. ACCORDING TO THE COMPLAINANT, DURING UNPACKING, IT WAS NOTED THAT A CREAM COLORED RESIDUE WAS FOUND ON THE BALLOON. REPORTEDLY, THIS WAS FOUND PRIOR TO USE WITH A PATIENT OR PROCEDURE. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX DILATATION BALLOON CATHETER KIT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9202137 ↗
  • MalfunctionOct 2, 2019Burst Container or Vessel; Burst Container or Vessel

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX DILATATION BALLOON CATHETER KIT WAS USED DURING A PROCEDURE PERFORMED ON AN UNKNOWN DATE. ACCORDING TO THE COMPLAINANT, THE BALLOON POPPED AT THE VERY END OF THE PROCEDURE. A PHOTO SENT BY THE CUSTOMER HAS CONFIRMED THAT THE BALLOON RUPTURED. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE STABLE. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION REGARDING THIS EVENT HAVE BEEN UNSUCCESSFUL TO DATE. SHOULD ADDITIONAL RELEVANT DETAILS BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9145042 ↗
  • MalfunctionJun 4, 2019Burst Container or Vessel; Burst Container or Vessel

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A NEPHROMAX BALLOON CATHETER WAS USED IN THE KIDNEY DURING A CYSTOSCOPY PROCEDURE PERFORMED ON (B)(6) 2019. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THE BALLOON WAS ATTEMPTED TO BE INFLATED; HOWEVER, THE BALLOON BURST. THE PROCEDURE WAS COMPLETED WITH ANOTHER NEPHROMAX BALLOON CATHETER. THERE HAVE BEEN NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8666486 ↗