Skip to content

Spiral Drill, PRS Phoenix, D=2.5mm, L=220mm, AO Connector 61254-220Recalls & reported problems

I.T.S. GmbH · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 09120116972020), received between Jul 28, 2022 and Jul 28, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 28, 2022Fracture; Fracture

    PATIENT SCHEDULED TO COMPLETE A SURGICAL PROCEDURE FOR FRACTURE OF THE ANTERIOR PELVIS AND POSTERIOR ACETABULUM. DURING THE DEVELOPMENT OF THE SURGERY, THE DOCTOR REQUIRES DRILLS WITH A DIAMETER OF 2.5 MM, SHORT AND LONG, TO PERFORM THE BROCADE PROCEDURE, MEASUREMENT, AND LATER IMPLANTATION OF THE CORTICAL SCREWS WITH A DIAMETER OF 3.5MM AND PLATE FIXATION. AFTER HAVING IMPLANTED THE SECOND SCREW AND WHEN THE DOCTOR WAS PREPARING TO DRILL FOR THE IMPLANTATION OF THE THIRD SCREW, THE SPIRAL DRILL WITH A DIAMETER OF 2.5 MM, LENGTH 220 MM (REFERENCE: (B)(4)) SPLITS, LEAVING THE TIP AT BONE LEVEL WITHIN THE PATIENT. THE DOCTOR TRIES TO EXTRACT THE FRAGMENT OF THE DRILL BIT THAT IS IN THE PATIENT, BUT IT IS NOT POSSIBLE BECAUSE HE HAD A COMMINUTED FRACTURE AND IN ADDITION TO THIS HE HAS TO REPOSITION THE LOCATION OF THE SCREW TO BE IMPLANTED. THE DOCTOR CONTINUED WITH THE SURGERY, SO HE REQUIRED THE SPIRAL DRILL, DIAMETER 2.5 MM, LENGTH 305 MM (REFERENCE: (B)(4)) TO BE ABLE TO CONTINUE, BUT WHEN HE WAS DRILLING FOR THE IMPLANTATION OF THE LAST SCREW OF 12 IMPLANTED, THIS OTHER DRILL BIT ALSO BREAKS AND LIKE THE PREVIOUS ONE, THE TIP REMAINS AT THE BONE LEVEL INSIDE THE PATIENT.

    Patient problems: Insufficient Information

    MAUDE report 15121469 ↗

Other Bit, Drill devices

All Bit, Drill devices →