CUSA® Clarity C7411SEARecalls & reported problems
Integra Lifesciences (Ireland) Limited · CUSA® Clarity 36kHz Curved Extended Micro Tip™ · Class U
All models of CUSA Clarity (21)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780126409), received between May 5, 2023 and May 5, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Overheating of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Overheating of Device1
Patient problems
- Superficial (First Degree) Burn1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 5, 2023Overheating of Device; Overheating of Device
THIS IS 2 OF 3 REPORTS LINKED TO MFG REPORT NUMBERS: 3006697299-2023-00044. 3006697299-2023-00046. A FACILITY REPORTED THAT CUSA CLARITY 36KHZ CURVED EXTENDED MICROTIP (C7411SEA) WAS USED DURING A "CRANIOTOMY OCCIPITAL RIGHT SIDE" FOR TUMOR REMOVAL, AND THE PATIENT RECEIVED A SUPERFICIAL BURN ON THE RIGHT SCAPULA AND WAS GIVEN FIRST AID TREATMENT WITH BETADINE AND A DUODERM DRESSING. THE HANDPIECE WAS APPARENTLY RESTED ON THE SCAPULA ON TOP OF THE SURGICAL DRAPE. THE SURGEON'S GOWN HAD A BURN THROUGH HIS SURGICAL GOWN BUT HAD NO PERSONAL INJURY. THERE WAS NO DELAY IN SURGERY REPORTED.
Patient problems: Superficial (First Degree) Burn
MAUDE report 16877461 ↗
Other Instrument, ultrasonic surgical devices
- Harmonic ACE HARH36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical4 deaths7,609 reports
- Harmonic HARHD36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical1 recall2 deaths5,037 reports
- Harmonic ACE HAR36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical2,726 reports
- Harmonic HAR1136Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical2 deaths1,538 reports
- THUNDERBEAT 5 mm,35 cm, Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical3 recalls1,373 reports
- THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical3 recalls2 deaths1,128 reports
- THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical2 recalls1 death970 reports
- Harmonic ACE HARH23Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical935 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page