CUSA® Clarity C7421SRecalls & reported problems

Integra Lifesciences (Ireland) Limited · CUSA® Clarity 23kHz Single-Sided Bone Tip · Class U

All models of CUSA Clarity (21)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780536369), received between Nov 15, 2024 and Nov 15, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Radiation Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Radiation Leak1

Patient problems

  • Unspecified Tissue Injury1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 15, 2024Radiation Leak; Radiation Leak

    A FACILITY REPORTED THAT THE USA CLARITY 23KHZ SINGLE SIDED BONE TIP (C7421SEA) WAS USED FOR AN "INTRACRANIAL TUMOR REMOVAL SURGERY¿, AND WHEN CUTTING THE INTERNAL AUDITORY MEATUS, DAMAGE WAS OBSERVED IN THE DURA MATER. THE SETTING OF THE DEVICE WHEN THE ISSUE OCCURRED: AMPLITUDE 80, TISSUE SELECT 0, ASPIRATION 90, IRRIGATION 10. THE SURGEON WAS NOT SURE IF THE DEVICE TOUCHED THE DURA MATER AND SUSPECTED THAT THE DEVICE IRRADIATED ULTRASONIC WAVES. HOWEVER, THE SURGEON WAS INITIALLY PLANNING TO MAKE AN INCISION IN THE PART OF DURA MATER THAT WAS DAMAGED; THEREFORE, THE EVENT DID NOT INTERFERE WITH THE OVERALL PROCEDURE. THERE WAS NO DELAY IN SURGERY, AND THE SAME DEVICE WAS USED TO COMPLETE THE SURGERY. ADDITIONAL INFORMATION RECEIVED INDICATING THE FOLLOWING: THE DEVICE DID NOT FALL OUT OF THE "DUTY CYCLE". ITS OUTPUT SETTING DURING PROCEDURE WAS AS FOLLOWS; AMPLITUDE 80, TISSUE SELECT 0, ASPIRATION 90, IRRIGATION 10. WHEN THE SALES REP ATTENDED THE SURGERY, IT SEEMED LIKE THE SURGENT DID NOT PUT TOO MUCH LOAD ON THE TIP. OTHER OUTPUT DEVICES WERE NOT USED AT THE SAME TIME.

    Patient problems: Unspecified Tissue Injury

    MAUDE report 20699155 ↗

Other Instrument, ultrasonic surgical devices

All Instrument, ultrasonic surgical devices →