S-ROM 53-4500RRecalls & reported problems
Depuy (Ireland) · S-ROM EXTRACTOR SLEEVE SPA & ZT · Class 1
All models of S-ROM (185)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10603295171980), received between Dec 16, 2019 and Jul 14, 2022 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
- Contamination /Decontamination Problem1
- Corroded1
- Device-Device Incompatibility1
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 14, 2022Corroded; Contamination /Decontamination Problem; Corroded; Contamination /Decontamination Problem
IT WAS REPORTED THAT THE HOSPITAL RECEIVED DIRTY INSTRUMENTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15014371 ↗MalfunctionJun 2, 2022Material Deformation; Material Deformation
IT WAS REPORTED THAT THE SLEEVE EXTRACTOR BENT DURING EXTRACTION. NO REPORTED SURGICAL DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14572275 ↗MalfunctionDec 16, 2019Break; Device-Device Incompatibility; Break; Device-Device Incompatibility
ADDITIONAL INFORMATION RECEIVED INDICATING THAT NOTHING WAS DELAYED. THE SLEEVE EXTRACTOR WAS NOT ABLE TO BE REMOVED AND THE LOOP BROKE AT THE LOOP.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9475834 ↗
FDA clearance and classification
The FDA regulates product code HWB (extractor) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the S-ROM 53-4500R
Has the S-ROM 53-4500R been recalled?
No FDA recall record in our data names this exact device identifier (DI 10603295171980), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the S-ROM 53-4500R?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Dec 16, 2019 and Jul 14, 2022. In those reports, the most common specific device problems are “Break” (1), “Contamination /Decontamination Problem” (1) and “Corroded” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the S-ROM 53-4500R?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the S-ROM 53-4500R FDA approved?
Devices of this type (product code HWB) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Depuy (Ireland).
Who makes the S-ROM 53-4500R, and is it still sold?
The FDA's device database lists Depuy (Ireland) as the company responsible for it (brand S-ROM, model 53-4500R). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other EXTRACTOR devices
- ATTUNE 2545-00-138Depuy (Ireland) · EXTRACTOR390 reports
- PINNACLE 2217-50-001Depuy (Ireland) · EXTRACTOR242 reports
- RECLAIM 2975-00-635Depuy (Ireland) · EXTRACTOR156 reports
- ATTUNE 2545-00-060Depuy (Ireland) · EXTRACTOR150 reports
- ESC PINNACLE 2218-00-010Depuy (Ireland) · EXTRACTOR150 reports
- NA 2125-00-600Depuy Orthopaedics, Inc. · EXTRACTOR129 reports
- P.F.C. 86-5226Depuy (Ireland) · EXTRACTOR80 reports
- NA 03.010.000Synthes GmbH · EXTRACTOR69 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page