Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10603295433224), received between Aug 30, 2017 and Aug 30, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Material Separation” (1 report).
9 other recalls cover devices cleared under the same FDA submission (K133834, K170748); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Separation1
Patient problems
- Foreign Body Reaction1
- Synovitis1
- Tissue Damage1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 30, 2017Material Separation; Material Separation
SECOND REVISION OF A BROKEN GLOBAL UNITE HEAD PLANNED FOR (B)(6) 2017. FIRST REVISION OCCURRED ON (B)(6) 2017 FOR THE EXACT SAME ISSUE. THE SURGEON WILL IMPLANT A REVERSE PROSTHESIS. UPDATE 7-31-2017: TRANSLATED MEDICAL RECORDS (B)(6) 2017 HAVE BEEN REVIEWED. OPERATIVE NOTE INDICATES THE PATIENT RECEIVED A REVISION LEFT TOTAL SHOULDER THROUGH REVERSAL OF ENTIRE PROSTHESIS AND SYNOVECTOMY DUE TO DISASSEMBLY OF PROSTHETIC HEAD THROUGH HUMERAL PROSTHESIS OF THE LEFT SHOULDER. THE SURGEON NOTES SYNOVIAL HYPERTROPHY WITH NUMEROUS METAL INCLUSIONS AT THE LOWER PART OF THE SUBSCAPULARIS. HE ALSO NOTES THAT THE PROSTHESIS HEAD HAS DISASSEMBLED FROM THE METAPHYSEAL MORSE TAPER AND IS LOOSE IN THE JOINT. HE NOTES SYNOVIAL HYPERTROPHY WITH METALLOSIS, PREVAILING ON THE GLENOID SIDE. PLEASE NOTE, THE HUMERAL HEAD WAS INITIALLY REPORTED AS BROKEN/FRACTURED, HOWEVER, THE MEDICAL RECORDS INDICATE IT BECAME DISASSEMBLED FROM THE HUMERAL PROSTHESIS, NOT FRACTURED. UPDATED ON 8-15-2017.
Patient problems: Foreign Body Reaction; Synovitis; Tissue Damage
MAUDE report 6829957 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K133834, K170748. One submission often covers many models, so check the product and lot details in each record.
- Z-0489-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 14 Product Code: 110014100
- Z-0488-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 12 Product Code: 110012100
- Z-0485-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE REV STEM SZ 8 Part Number: 110008600
- Z-0487-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE REV STEM SZ 10 Product Code: 110010600
- Z-0486-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 10 Part Number: 110010100
- Z-0483-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 6 Part Number: 11000610
- Z-0484-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 8 Part Number: 110008100
- Z-0490-2022 · Dec 7, 2021 · TerminatedGLOBAL UNITE STD STEM SZ 16 Product Code: 110016100
- Z-1012-2018 · Nov 28, 2017 · TerminatedThe GLOBAL UNITE Platform Shoulder System is intended for cemented or uncemented total shoulder or hemi-shoulder replacement procedures, Product labeling: LEO-1100-30-000 REV D.pd
Other PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED devices
- DJO SURGICAL 509-02-032Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED364 reports
- DELTA XTEND 130790036Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED171 reports
- DELTA XTEND 130770018Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED159 reports
- TRIGEN 71118200Smith & Nephew, Inc. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED123 reports
- DJO SURGICAL 509-02-432Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED119 reports
- DELTA XTEND 130738206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED116 reports
- COMPREHENSIVE SHOULDER SYSTEM 113633Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED2 recalls4 reports
- DELTA XTEND 130742206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED99 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page