Skip to content

ATTUNE 2546-00-440Recalls & reported problems

Depuy (Ireland) · ATTUNE KNEE SYSTEM REVISION FEMORAL SLEEVE TAPER SEPARATOR BASE · Class 1

All models of ATTUNE (1475)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10603295440482), received between Jun 10, 2022 and Jun 10, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility5
  • Naturally Worn4
  • Material Deformation2

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 10, 2026Device-Device Incompatibility; Material Deformation

    IT WAS REPORTED THAT FEMORAL SLEEVE SEPARATOR BASE WAS CROSS THREADED INTO THE ATTUNE REVISION FEMUR. THE SURGEON WAS NOT ABLE TO REMOVE IT FROM THE FEMUR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25456885 ↗
  • MalfunctionJan 6, 2025Device-Device Incompatibility; Material Deformation; Device-Device Incompatibility; Material Deformation

    IT WAS REPORTED THAT DURING A KNEE SURGERY ON (B)(6) 2024, THE THREADS ON THE ASSEMBLY SLEEVE SEPARATOR WAS DAMAGED AND WOULD NOT THREAD INTO THE SLEEVE. THE PUSH ROD WAS ALSO BENT. THE SURGERY WAS NOT DELAYED DUE TO THESE ISSUES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21079809 ↗
  • MalfunctionOct 14, 2024Device-Device Incompatibility; Naturally Worn; Device-Device Incompatibility; Naturally Worn

    IT WAS REPORTED THE ADAPTOR AND SEPARATOR BASE ITEMS WOULD NOT THREAD INTO ATTUNE REVISION FEMUR AS PER SURGICAL TECHNIQUE STATES. ATTUNE REVISION 6MM HEX DRIVER WOULD ALLOW ITEMS TO CONNECT; THERE IS POSSIBLE DAMAGE TO THREADS OR CONNECTION POINT WITH HEX DRIVER. THE SEPARATOR ROD GOT BENT IN THE PROCESS OF TRYING TO USE THE KIT. THE EVENT WAS MANAGED BY USING OSTETOTOMES, GIGLI SAWS AND ALTERNATIVE INSTRUMENTATION TO TRY AND REMOVE. THE PROCEDURE WAS PROLONGED BY TEN (10) MINUTES; THERE WAS NO CONSEQUENCE TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20439755 ↗
  • MalfunctionDec 5, 2022Device-Device Incompatibility; Naturally Worn; Device-Device Incompatibility; Naturally Worn

    IT WAS REPORTED THAT THE FEMORAL SLEEVE SEPARATOR BASE DIDN'T SEEM TO EVER THREAD INTO THE FEMUR CORRECTLY AND WOULD PULL OFF PRIOR TO DISENGAGEMENT. TIBIAL SLEEVE SEPARATOR BASE AND TIBIAL SLEEVE SEPARATOR WEDGE STAYED ATTACHED TO THE TIBIAL TRAY. THE THREADS WERE STRIPPED ON THE TAPER BASE. THERE WAS A SURGICAL DELAY OF 2 HOURS. THE PROCEDURE WAS COMPLETED WITHOUT COMPLICATIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15915823 ↗
  • MalfunctionJun 17, 2022Naturally Worn; Naturally Worn

    CROSS THREADED AND PUSH PINS BROKE IN HALF. NO ADVERSE AFFECTS ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14737795 ↗
  • MalfunctionJun 10, 2022Device-Device Incompatibility; Naturally Worn; Device-Device Incompatibility; Naturally Worn

    IT WAS REPORTED THAT THE SEPARATOR BASE SCREW THREAD DAMAGED SO DID NOT ATTACH TO THE FEMORAL COMPONENT. PATIENT NOT AFFECTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14655928 ↗

Other EXTRACTOR devices

All EXTRACTOR devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page