MONARCH 277030105Recalls & reported problems
Medos International Sàrl · MONARCH SPINE SYSTEM ROD HOLDER · Class 1
All models of MONARCH (13)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034196602), received between Nov 21, 2019 and Nov 21, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 21, 2019Break; Break
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT PATIENT UNDERWENT A POSTERIOR LUMBAR SPINAL FUSION (L2-SAI) TREATING DEGENERATIVE DISEASE ON (B)(6) 2019. THE SURGEON TRIED TO REMOVE A FORMERLY IMPLANTED CFS7.0-45MM SCREW ON L3 LEFT AND IMPLANT A CFS8.0-45MM SCREW INSTEAD. BECAUSE THE NEW SCREW SEEMED TIGHT (STICKING OUT APPROXIMATELY 2MM THAN EXPECTED), THE SURGEON TRIED TO REMOVE IT. THEN, THE FOLLOWING EVENTS OCCURRED IN SEQUENCE: THE TIP OF THE DRIVER SHAFT BROKE. AS THE SURGEON TRIED TO REMOVE THE SCREW BY FIXING A ROD AND A SETSCREW, THE SCREW HEAD OF THE CORTICAL FIX SCREW CAME OFF. THE ROD HOLDER BROKE. THE SURGEON DECIDED TO LEAVE THE FRAGMENTED CORE OF THE CORTICAL FIX SCREW IN THE PATIENT¿S BODY DUE TO THE LIMITED SURGICAL TIME. SINCE L3 LEFT WAS NOT FIXED, THE SCREW STABILIZATION HAS DECREASED A LITTLE. THE PATIENT IS RECOVERING. CONCOMITANT DEVICES: SETSCREWS (PART: UNKNOWN, LOT: UNKNOWN, QUANTITY: UNKNOWN), ROD (PART: UNKNOWN, LOT: UNKNOWN, QUANTITY: UNKNOWN). THIS REPORT IS FOR A FORCEPT ROD HOLDER, STRAIGHT. THIS IS REPORT 2 OF 3 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9355526 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page