NA 03.820.100Recalls & reported problems
Synthes GmbH · AWL 12MM · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10705034731360), received between Feb 1, 2019 and Sep 10, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Failure to Cut” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Cut5
- Material Twisted/Bent3
- Break1
- Scratched Material1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Insufficient Information1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 10, 2026Failure to Cut
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50715131 ↗MalfunctionMar 6, 2024Failure to Cut; Material Twisted/Bent; Scratched Material; Failure to Cut; Material Twisted/Bent; Scratched Material
IT WAS REPORTED THAT ON (B)(6) 2024 DURING PRE-SURGICAL CHECK, IT WAS FOUND THAT THE TIP OF THE AWL IN QUESTION WAS NOT SHARP. THE AWL WAS BENT AND NICKED. THERE WAS NO PATIENT OR PROCEDURE INTERACTION. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR AN AWL 12MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18845762 ↗MalfunctionNov 27, 2023Failure to Cut; Material Twisted/Bent; Failure to Cut; Material Twisted/Bent
IT WAS REPORTED THAT ON UNKNOWN DATE, DURING SURGERY AN AWL WAS DISCOVERED TO HAVE A BENT TIP. AWL HAD GONE THROUGH THE SOFT PLASTIC TIP AND THE END WAS BENT. THEY DIDN'T KNOW IF THIS WAS DAMAGED DURING SHIPPING OR IF IT HAD BEEN RETURNED FROM THE FIELD WITH A BENT TIP. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. PROCEDURE AND PATIENT OUTCOME WERE UNKNOWN. THIS REPORT IS FOR ONE (1) AWL 12MM. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: Insufficient Information
MAUDE report 18212662 ↗MalfunctionAug 3, 2021Failure to Cut; Failure to Cut
DEVICE REPORT FROM SYNTHES (B)(4) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THE AWL WAS DULL AND DIFFICULT TO USE. THE AWL WAS ABLE TO BE USED FOR SURGERY ANYWAY. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO DELAY. THIS REPORT IS FOR AN AWL. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12269091 ↗MalfunctionMay 7, 2021Failure to Cut; Failure to Cut
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT DURING A PROCEDURE ON (B)(6) 2021, THE SURGEON WAS USING THE AWL AND NOTED THAT IT WAS BLUNT. THE SURGEON WAS ABLE TO CONTINUE TO USE THE AWL, HOWEVER. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO DELAY. THERE WAS NO PATIENT CONSEQUENCE. THIS REPORT IS FOR A AWL 12MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11790624 ↗MalfunctionFeb 1, 2019Break; Material Twisted/Bent; Break; Material Twisted/Bent
IT WAS REPORTED THAT ON (B)(6) 2019, THE AWL BROKE AND HAS A BENT TIP DURING A PRODISC-C PROCEDURE. IT IS UNKNOWN IF THE TIP WAS BENT PRIOR TO PROCEDURE OR WHILE IT WAS BEING USED. THE SURGEON DID NOT HAVE ANY ISSUES WHILE USING THE DEVICE. NO FRAGMENTS WERE GENERATED FROM BROKEN DEVICE. IT IS UNKNOWN IF THERE WAS SURGICAL DELAY. PROCEDURE WAS SUCCESSFULLY COMPLETED. PATIENT STATUS IS UNKNOWN. THIS REPORT IS FOR ONE (1) AWL 12MM. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8298841 ↗
Other AWL devices
- Meridian RA2-003015Seaspine Orthopedics Corporation · AWL1 recall1 report
- AMP 117-165Alphatec Spine, Inc. · AWL1 recall0 reports
- SYNFIX Evolution 03.835.032Synthes GmbH · AWL16 reports
- NA 359.213Synthes GmbH · AWL7 reports
- NA 03.010.041Synthes GmbH · AWL7 reports
- ENDOSKELETON® TAS 2300-1110Medtronic Sofamor Danek, Inc. · AWL7 reports
- Endoskeleton™ TCS Interbody System 5210-1063Medtronic Sofamor Danek, Inc. · Awl5 reports
- NA 03.010.040Synthes GmbH · AWL4 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page