ECHELON; ENDOPATH ECR60BRecalls & reported problems

Ethicon Endo-Surgery, LLC · Endoscopic Linear Cutter Reloads Blue 3.5mm · Class 2 · Implant

All models of ECHELON ENDOPATH (31)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Echelon stapler cartridge from Ethicon holds staples used in minimally invasive surgery to join and cut tissue. The FDA database holds 545 reports for it, most describing staples that do not form properly or fail to fire, with 60 injuries and 1 death. No recalls name this device. Reports fell from 73 in the previous 12 months to 8 in the last 12 months.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
545
Deaths reported
1
Injuries reported
60
Recalls naming it
0

Summary

The FDA's MAUDE database contains 545 adverse event reports that list this exact device (DI 10705036001775), received between Dec 14, 2017 and Mar 13, 2026 — classified as 1 death, 60 injuries, 484 malfunctions.

The most frequently reported specific device problem is “Failure to Form Staple” (283 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 5 reportsDec 2023: 1 reportsJan 2024: 4 reportsFeb 2024: 8 reportsMar 2024: 1 reportsApr 2024: 9 reportsMay 2024: 8 reportsJun 2024: 9 reportsJul 2024: 8 reportsAug 2024: 6 reportsSep 2024: 16 reportsOct 2024: 3 reportsNov 2024: 6 reportsDec 2024: 11 reportsJan 2025: 14 reportsFeb 2025: 2 reportsMar 2025: 3 reportsApr 2025: 2 reportsMay 2025: 4 reportsJun 2025: 9 reportsJul 2025: 3 reportsAug 2025: 9 reportsSep 2025: 2 reportsOct 2025: 8 reportsNov 2025: 2 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 2 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202616
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Form Staple283
  • Failure to Fire105
  • Adverse Event Without Identified Device or Use Problem33
  • No Apparent Adverse Event27
  • Material Integrity Problem22
  • Manufacturing, Packaging or Shipping Problem14
  • Device Misassembled During Manufacturing /Shipping12
  • Ejection Problem12

Patient problems

  • No Clinical Signs, Symptoms or Conditions357
  • No Consequences Or Impact To Patient133
  • Hemorrhage/Blood Loss/Bleeding35
  • No Code Available25
  • Failure to Anastomose23
  • Blood Loss15
  • Fistula6
  • Insufficient Information6

Recent adverse event reports

The 25 most recent of 545 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 13, 2026Failure to Fire

    IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE FIRING SEQUENCE SUDDENLY STOPPED; AND THE REVERSE BUTTON WAS USED. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24591537 ↗
  • MalfunctionMar 3, 2026Failure to Fire

    IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE DEVICE WOULD NOT FIRE. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24500626 ↗
  • MalfunctionFeb 11, 2026Device Misassembled During Manufacturing /Shipping

    IT WAS REPORTED THAT DURING AN UNKNOWN SURGERY, BEFORE USED ON THE PATIENT, NOTED THERE ARE FOREIGN MATTERS IN THE PACKING. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24316038 ↗
  • MalfunctionFeb 11, 2026Failure to Fire

    IT WAS REPORTED THAT DURING AN UNKNOWN SURGERY, COULD NOT FIRE. CHANGED THE NEW ONE TO COMPLETE SURGERY. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24314618 ↗
  • MalfunctionJan 9, 2026Failure to Form Staple

    IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24022647 ↗
  • MalfunctionDec 21, 2025Failure to Form Staple; No Apparent Adverse Event; Failure to Form Staple; No Apparent Adverse Event

    IT WAS REPORTED THAT DURING A LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT SOME STAPLES MALFORMED AND OOZING OCCURRED. SUTURE WAS USED TO OVERSEW. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: Hemorrhage/Blood Loss/Bleeding; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23860607 ↗
  • MalfunctionNov 13, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAP GASTRIC SLEEVE PROCEDURE, IT WAS OBSERVED THAT THE RELOAD DID NOT LEAD TO A B-FORMED SHAPE AS 4-5 PINS LOOKED OPEN ONCE FIRING COMPLETED. THE SURGEON DID OMENTOPEXY FOR SAFETY AND COMPLETED THE CASE. THERE WAS NO BLEEDING OR OOZING REPORTED. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23542232 ↗
  • MalfunctionNov 13, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAP GASTRIC SLEEVE PROCEDURE, IT WAS OBSERVED THAT THE RELOAD DID NOT LEAD TO A B-FORMED SHAPE AS 4-5 PINS LOOKED OPEN ONCE FIRING COMPLETED. THE SURGEON DID OMENTOPEXY FOR SAFETY AND COMPLETED THE CASE. THERE WAS NO BLEEDING OR OOZING REPORTED. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23542205 ↗
  • MalfunctionOct 31, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED ON THE THIRD, FOURTH AND FIFTH FIRING. CHANGED THE NEW ONE TO COMPLETE SURGERY. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23438966 ↗
  • MalfunctionOct 31, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED ON THE THIRD, FOURTH AND FIFTH FIRING. CHANGED THE NEW ONE TO COMPLETE SURGERY. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23438818 ↗
  • MalfunctionOct 31, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED ON THE THIRD, FOURTH AND FIFTH FIRING. CHANGED THE NEW ONE TO COMPLETE SURGERY. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23438814 ↗
  • MalfunctionOct 29, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO ANOTHER THREE TO CONTINUE THE SURGERY BUT THE SAME PROBLEM HAPPENED AGAIN. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23417427 ↗
  • MalfunctionOct 29, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO ANOTHER THREE TO CONTINUE THE SURGERY BUT THE SAME PROBLEM HAPPENED AGAIN. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23417426 ↗
  • MalfunctionOct 29, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO ANOTHER THREE TO CONTINUE THE SURGERY BUT THE SAME PROBLEM HAPPENED AGAIN. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23417421 ↗
  • MalfunctionOct 29, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO ANOTHER THREE TO CONTINUE THE SURGERY BUT THE SAME PROBLEM HAPPENED AGAIN. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23417418 ↗
  • MalfunctionOct 27, 2025Ejection Problem; Ejection Problem

    IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE OF THE ESOPHAGUS, THE SURGEON NOTED THAT IT WAS VERY DIFFICULT TO INSTALL THE CARTRIDGE AFTER OPENING THE PACKAGE. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23397198 ↗
  • MalfunctionSep 10, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    THE DEVICE WAS RECEIVED WITH NO COMPLAINT INFORMATION. ATTEMPTS WERE MADE TO RECONCILE THE DEVICE WITH NO SUCCESS RESULTING IN THE CREATION OF A NEW COMPLAINT. AWB 391120895591 RECEIVED 07/28/2025. BOX MARKED AS (B)(4) ON AWB 391120895591; RECD ECR60B; LOT#: 965A82; ECM HAS GST60B; LOT#: 887C43 FROM COUNTRY CHINA.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23014873 ↗
  • MalfunctionSep 8, 2025Failure to Fire; Failure to Fire

    THE CARTRIDGE WAS NOT USED BECAUSE IT DID NOT COVER THE TISSUE. IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE DEVICE COULD NOT BE FIRED. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22992443 ↗
  • MalfunctionAug 20, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A COLON RESECTION PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22850002 ↗
  • MalfunctionAug 18, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LUNG RESECTION PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22833414 ↗
  • MalfunctionAug 18, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LUNG RESECTION PROCEDURE, IT WAS OBSERVED THAT SOME STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22833151 ↗
  • MalfunctionAug 18, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LUNG RESECTION PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22828577 ↗
  • MalfunctionAug 18, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT, DURING A LUNG RESECTION PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22827086 ↗
  • MalfunctionAug 18, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LUNG RESECTION PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22826927 ↗
  • MalfunctionAug 16, 2025Failure to Form Staple; Failure to Form Staple

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC LOBECTOMY PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. THEY CHANGED TO ANOTHER TWO RELOADS TO CONTINUE THE SURGERY BUT THE SAME PROBLEM HAPPENED AGAIN. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22823190 ↗

Other STAPLE, IMPLANTABLE devices

All STAPLE, IMPLANTABLE devices →