Harmonic HAR745Recalls & reported problems
Ethicon Endo-Surgery, LLC · Harmonic 700 Shears, Advanced Hemostasis · Class U
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 10705036035787), received between Nov 6, 2024 and Mar 30, 2026 — classified as 1 injury, 8 malfunctions.
The most frequently reported specific device problem is “Material Separation” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Material Separation3
- Delivered as Unsterile Product2
- Adverse Event Without Identified Device or Use Problem1
- Failure to Read Input Signal1
- Noise, Audible1
- Patient Device Interaction Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
- Failure to Anastomose1
- Hemorrhage/Blood Loss/Bleeding1
- Pleural Effusion1
- Pneumonia1
- Unspecified Tissue Injury1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 30, 2026Material Separation
IT WAS REPORTED THAT DURING THE CONVERSION OF SLEEVE TO BYPASS PROCEDURE, THE ACTIVE BLADE OF THE HARMONIC DEVICE BROKE, AND A PIECE OR REMNANT FELL OFF INTO THE PATIENT'S BODY, BUT IT WAS RETRIEVED. NO X-RAY WAS DONE BUT THEY WERE ABLE TO VISUALLY SEE THE REMNANT AND RETRIEVED IT. THE PATIENT IS DOING FINE NOW.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24731157 ↗MalfunctionMar 13, 2026Failure to Read Input Signal
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THE SCREEN OF THE GENERATOR WAS GIVING THE RELAX PRESSURE ERROR CODE EVEN THOUGH THE JAWS WERE OPEN. NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24591486 ↗MalfunctionFeb 12, 2026
SURGEON TRIED USING THE HARMONIC 700 SERIES SHEARS, BUT THE DEVICE WAS NOT FUNCTIONAL AND WOULD NOT SEAL. A SECOND HARMONIC 700 SERIES SHEARS WAS OPENED AND WAS FUNCTIONAL. MINIMAL DELAY, NO IDENTIFIED HARM.
Patient problems: Failure to Anastomose
MAUDE report 24321481 ↗InjuryJan 23, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING A SLEEVE GASTRECTOMY PROCEDURE THAT THERE WAS A LOT BLEEDING/OOZING ON THE STAPLE LINE. A CLIP APPLIER WAS USED TO STOP THE BLEEDING/OOZING. THERE WERE NO ADVERSE CONSEQUENCES REPORTED.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 24162468 ↗MalfunctionSep 8, 2025Material Separation; Material Separation
IT WAS REPORTED DURING AN UNKNOWN PROCEDURE THAT THE ACTIVE BLADE FELL COMPLETELY OFF. BLADE WAS RETRIEVED AND THE DEVICE WAS CHANGED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22993038 ↗MalfunctionJun 9, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT FOR A CLINICAL TRIAL PATIENT (B)(6) DURING A UPPER GASTROINTESTINAL PROCEDURE THE PATIENT EXPERIENCED SUBCUTANEOUS EMPHYSEMA OF THE CHEST WALL, DYSPHAGIA, PNEUMONIA, AND LEFT PLEURAL EFFUSION. THE SUBCUTANEOUS EMPHYSEMA OF THE CHEST WALL HAS A CAUSAL RELATIONSHIP WITH THE PROCEDURE AND NOT RELATED TO THE DEVICE. THE DYSPHAGIA HAS A CAUSAL RELATIONSHIP WITH THE PROCEDURE AND NOT RELATED TO THE DEVICE. THE PNEUMONIA HAS A POSSIBLE RELATIONSHIP WITH THE PROCEDURE AND NOT RELATED TO THE DEVICE. IT WAS TREATED WITH DRUG THERAPY. THE LEFT PLEURAL EFFUSION HAS A CAUSAL RELATIONSHIP WITH THE PROCEDURE AND NOT RELATED TO THE DEVICE. IT WAS TREATED WITH A PIGTAIL CHEST TUBE INSTALLATION
Patient problems: Pleural Effusion; Pneumonia; Unspecified Tissue Injury
MAUDE report 22166263 ↗MalfunctionJan 24, 2025Delivered as Unsterile Product; Delivered as Unsterile Product
IT WAS REPORTED PRIOR TO AN UNKNOWN PROCEDURE THE WHITE INNER BOXES THE PLASTIC IS BROKE AND AIR IS BEING LET IN. AT THE TIME OF THE CALL IT WAS UNKNOWN IF THE BROWN OUTER BOX WAS DAMAGED. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21232761 ↗MalfunctionJan 24, 2025Delivered as Unsterile Product; Delivered as Unsterile Product
IT WAS REPORTED PRIOR TO AN UNKNOWN PROCEDURE THE WHITE INNER BOXES THE PLASTIC IS BROKE AND AIR IS BEING LET IN. AT THE TIME OF THE CALL IT WAS UNKNOWN IF THE BROWN OUTER BOX WAS DAMAGED. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21232738 ↗MalfunctionNov 6, 2024Material Separation; Noise, Audible; Material Separation; Noise, Audible
IT WAS REPORTED THAT, AT THE END OF THE MYOMECTOMY OPERATION, THE ACTIVE BRANCH BROKE OFF. ACCORDING TO THE USER, THE GENERATOR EMITTED A DIFFERENT SOUND BEFORE THE BRANCH BROKE. IT IS NOT CLEAR WHETHER THE BROKEN PART WAS REMOVED AS A SUCTION CUP WAS USED DURING SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20621217 ↗
Other Instrument, ultrasonic surgical devices
- Harmonic ACE HARH36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical4 deaths7,609 reports
- Harmonic HARHD36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical1 recall2 deaths5,037 reports
- Harmonic ACE HAR36Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical2,726 reports
- Harmonic HAR1136Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical2 deaths1,538 reports
- THUNDERBEAT 5 mm,35 cm, Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical3 recalls1,373 reports
- THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical3 recalls2 deaths1,128 reports
- THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type S TB-0535FCSOlympus Medical Systems Corp. · Instrument, ultrasonic surgical2 recalls1 death970 reports
- Harmonic ACE HARH23Ethicon Endo-Surgery, LLC · Instrument, ultrasonic surgical935 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page