Solus G25685Recalls & reported problems
Cook Ireland Ltd · Solus, Double Pigtail Stent with Introducer · Class 2 · Implant
All models of Solus (7)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10827002256856), received between May 22, 2018 and Apr 29, 2021 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Difficult to Advance” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Advance2
- Improper or Incorrect Procedure or Method2
- Physical Resistance/Sticking1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 29, 2021Improper or Incorrect Procedure or Method; Physical Resistance/Sticking; Improper or Incorrect Procedure or Method; Physical Resistance/Sticking
THE INNER GUIDING CATHETER WAS NOT SEPARATED FROM THE PUSHING CATHETER(OUTER, COLOR IS PURPLE) WHEN THE STENT WAS TRIED TO BE PLACED IN THE BILE DUCT. THEY RE-STARTED STENT PLACED PROCEDURES, PLACED THE OTHER STENT ON THE BILE DUCT, AND FINISHED THE PROCEDURE. (THE STENT USED IS UNKNOWN). DID ANY SECTION OF THE DEVICE REMAIN INSIDE THE PATIENT BODY? NO. DID THE PATIENT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE? NO. DID THE PRODUCT CAUSE OR CONTRIBUTE TO THE NEED FOR ADDITIONAL PROCEDURE(S)? NO. WERE THERE ANY ADVERSE EFFECTS ON THE PATIENT DUE TO THIS OCCURRENCE? NO. DID THE PRODUCT CAUSE OR CONTRIBUTE TO THE ADVERSE EFFECT(S)? NO. PLEASE INDICATE WHERE THE DEVICE WAS STORED PRIOR TO USE. THIS PRODUCT WAS LOCATED IN THE ERCP ROOM PRIOR TO USE. WHAT IS THE REORDER NUMBER, OUTER DIAMETER AND LENGTH OF THE WIRE GUIDE THAT WAS USED WITH THIS DEVICE IN THIS PROCEDURE? VISIGLIDE 2 GUIDEWIRE - OUTER DIAMETER 0.025IN / LENGTH 450CM / TIP SHAPE ANGLED / FIRST USE. WERE PREVIOUS PROCEDURES I.E. SPHINCTEROTOMY ETC. CARRIED OUT PRIOR TO PLACING THE DEVICE OVER THE PARTICULAR WIRE GUIDE? IF YES PLEASE INDICATE THE PROCEDURE PERFORMED. SPHINCTEROTOMY. WAS THE WIRE GUIDE INSPECTED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11743758 ↗MalfunctionJan 13, 2021Improper or Incorrect Procedure or Method; Difficult to Advance; Improper or Incorrect Procedure or Method; Difficult to Advance
SUPPLEMENTAL REPORT IS BEING SUBMITTED DUE TO THE COMPLETION OF THE INVESTIGATION.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 11164179 ↗MalfunctionMay 22, 2018Difficult to Advance; Difficult to Advance
INITIAL MDR IS BEING SUBMITTED BASED ON THE DEVICE MALFUNCTION PRECEDENCE: ¿DIFFICULT ADVANCEMENT". AS REPORTED TO CUSTOMER RELATIONS, "TWO HOBBS FREEMAN 10X10 DOUBLE PIG TAIL STENTS WERE REMOVED FROM THE AMPULA. PHYSICIAN CANNULATED WITH A .035X450 JAG WIRE GUIDE THRU THE FUSION QUATRO EXTRACTION BALLOON. THREE SWEEPS OF THE BILE DUCT WERE PERFORMED AND PHYSICIAN LEFT THE LONG WIRE GUIDE IN POSITION AND HAD THE TECH PREPARE THE SOLUS 10X10 STENT FOR TRIAL. INTRODUCER GUIDING CATHETER WAS LIGHTLY LUBRICATED USING SURGI LUBE. STENT WAS LOADED ONTO GUIDING CATHETER AND THEN ONTO WIRE GUIDE. DIFFICULTY WAS EXPERIENCED ONCE IN THE DUCT GETTING THE STENT INTO POSITION. PHYSICIAN NOTED PUSHING CATHETER WAS BUCKLING AT THE BIOPSY PORT. GUIDING CATHETER WAS SLOWLY REMOVED ONCE THE PHYSICIAN HAD THE STENT INTO POSITION. GUIDING CATHETER STRETCHED AND BROKE MULTIPLE TIMES DURING REMOVAL. FINALLY, STENT WAS PLACED SUCCESSFULLY. PHYSICIAN WANTED TO PLACE A SECOND 10X10 DOUBLE PIG TAIL STENT, SO A HOBBS FREEMAN 10X10 DOUBLE PIGTAIL WAS LOADED ONTO A FUSION OASIS 10FR INTRODUCER. GUIDING CATHETER WAS LIGHTLY LUBED PRIOR TO STENT PLACEMENT. ONCE STENT INTO POSITION AND GUIDING CATHETER UP IN THE
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7533456 ↗
Other CATHETER, BILIARY, DIAGNOSTIC devices
- Hurricane™ RX M00545900Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls1 death705 reports
- MUSTANG™ H74939171060470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC384 reports
- CRE™ PRO M00558710Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC1 recall284 reports
- Hurricane™ RX M00545920Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls211 reports
- MUSTANG™ H74939171070470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC265 reports
- MUSTANG™ H74939171050470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC212 reports
- Hurricane™ RX M00545940Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC2 recalls109 reports
- MUSTANG™ H74939171100470Boston Scientific Corporation · CATHETER, BILIARY, DIAGNOSTIC203 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page