Zilver Flex 35 G50171Recalls & reported problems

Cook Incorporated · Zilver Flex 35 Biliary Self-Expanding Stent · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10827002501710), received between Nov 11, 2016 and May 1, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Difficult to Advance” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Advance1
  • Material Separation1
  • Off-Label Use1
  • Premature Activation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 1, 2024Premature Activation; Off-Label Use; Difficult to Advance; Premature Activation; Off-Label Use; Difficult to Advance

    AS REPORTED, DURING AN UNSPECIFIED ¿SINUS CASE¿, A ZILVER FLEX 35 BILIARY SELF-EXPANDING STENT BECAME STUCK IN A COOK SHEATH AND THE STENT PREMATURELY/PARTIALLY DEPLOYED. AS THE USER ATTEMPTED TO ADVANCE THE STENT THROUGH THE SHEATH, PART OF THE STENT CAME OUT OF THE SHEATH AND PART REMAINED STUCK INSIDE THE SHEATH. THE USER WAS UNABLE TO PULL THE STENT BACK INTO THE SHEATH. THE SHEATH THEN STARTED TO UNRAVEL (THIS EVENT WILL BE REPORTED UNDER PATIENT IDENTIFIER (B)(4). THE PART OF THE STENT THAT WAS OUTSIDE OF THE SHEATH THEN DEPLOYED IN THE PATIENT, WHILE PART OF THE STENT REMAINED STUCK IN THE SHEATH. THE USER REMOVED THE SHEATH FROM THE PATIENT, AND THE STENT CAME OUT WITH THE SHEATH. THE PROCEDURE WAS COMPLETED WITH ANOTHER COOK STENT AND ANOTHER MANUFACTURER¿S SHEATH. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19221982 ↗
  • MalfunctionNov 11, 2016Material Separation; Material Separation

    THE HUB DETACHED FROM THE STENT DELIVERY SYSTEM OUTSIDE OF THE INTRODUCER SO RETRIEVAL WITH ANOTHER DEVICE WAS NOT NECESSARY. ANOTHER STENT WAS USED TO COMPLETE THE PROCEDURE. THE PHYSICIAN WAS ABLE TO RETRIEVE WITHOUT PATIENT COMPLICATIONS. NO OTHER INFORMATION WAS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6097097 ↗