Hall 50 PRO7200BRecalls & reported problems
Conmed Corporation · HALL 50 DUAL TRIGGER BATTERY HANDPIECE · Class 1
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10845854040034), received between Aug 27, 2024 and Aug 27, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Unintended Ejection” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Unintended Ejection1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 27, 2024Unintended Ejection; Unintended Ejection
A SALES REPRESENTATIVE REPORTED ON BEHALF OF A CUSTOMER THAT THE PRO7200B, HALL 50 DUAL TRIGGER BATTERY HANDPIECE DEVICE WAS BEING USED DURING A TOTAL HIP PROCEDURE ON AN UNKNOWN DATE, AND ¿AN ATTACHMENT (PRO6045) CAME LOOSE FROM THE HAND PIECE THREE TIMES DURING THE SAME SURGERY. THE ATTACHMENT CAME LOOSE WHEN IT WAS PUT UNDER PRESSURE. ACCORDING TO THE STAFF AND SURGEON, IT WAS DUE TO THE HANDPIECE AND NOT THE ATTACHMENT. NO HARM CAME TO THE STAFF OR PATIENT¿. FOLLOW-UP ASSESSMENT FOUND THAT "THE ATTACHMENT CAME LOOSE WHEN IT WAS USED TO CUT OF COLLUM DURING A TOTAL HIP SURGERY. THE STAFF SAID THAT IT HAPPENED WHEN THE SAW WAS PUT UNDER PRESSURE DURING THE CUT. SO THE PRO6045 WAS IN THE WOUND WHEN IT CAME OFF. IT HAPPENED THREE TIMES DURING THIS STEP OF THE SURGERY, BUT THE SURGEON WAS ABLE TO COMPLETE THE CUT AND REMOVE THE COLLUM. IT CAME OFF IN ONE PIECE. NO COMPONENTS FELL OFF FROM THE PRO6045 ITSELF OR THE PRO7200B." THE PROCEDURE WAS COMPLETED WITHOUT THE USE OF AN ALTERNATE DEVICE. THERE WAS NO REPORTED DELAY AND NO REPORT OF INJURY, MEDICAL/SURGICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT. THE PRO6045, HALL SURGICAL POWERPRO RECIPROCATING SAW ATTACHMENT
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20075566 ↗
Other SAW, POWERED, AND ACCESSORIES devices
- DYONICS POWERMAX ELITE 72200616Smith & Nephew, Inc. · SAW, POWERED, AND ACCESSORIES4,290 reports
- NA 72200616SSmith & Nephew, Inc. · SAW, POWERED, AND ACCESSORIES486 reports
- NA 72201500Smith & Nephew, Inc. · SAW, POWERED, AND ACCESSORIES136 reports
- PLATINUM 72205321Smith & Nephew, Inc. · SAW, POWERED, AND ACCESSORIES118 reports
- Zimmer Biomet™ 89-8509-450-60Zimmer Surgical SA · Saw, Powered, And Accessories83 reports
- NA 72200617Smith & Nephew, Inc. · SAW, POWERED, AND ACCESSORIES77 reports
- NA 72202530Smith & Nephew, Inc. · SAW, POWERED, AND ACCESSORIES53 reports
- DYONICS INCISOR 72203013Smith & Nephew, Inc. · SAW, POWERED, AND ACCESSORIES46 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.