Carto 3 CB3412CTRecalls & reported problems
Biosense Webster Inc · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10846835003796), received between Jun 5, 2023 and Jun 5, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Contamination /Decontamination Problem” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K090017); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Contamination /Decontamination Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 5, 2023Contamination /Decontamination Problem; Contamination /Decontamination Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FLUTTER RIGHT (R-AFL) PROCEDURE WITH A CARTO® 3 SYSTEM INTERFACE CABLE AND FOREIGN MATERIAL INSIDE THE PACKAGING OUTSIDE OF SPECIFICATION ISSUE OCCURRED. THERE WAS A TINY PIECE OF CARDBOARD INSIDE THE STERILE PACKAGING OF THE CARTO® 3 SYSTEM INTERFACE CABLE. THE CARTO® 3 SYSTEM INTERFACE CABLE WAS REPLACED AND THE ISSUE RESOLVED. THE PROCEDURE CONTINUED. THERE WAS NO PATIENT CONSEQUENCE REPORTED. ADDITIONAL INFORMATION WAS RECEIVED. THE ISSUE WAS OBSERVED PRIOR TO THE PRODUCT BEING USED. THE CABLE WAS PACKAGED AND SENT FOR RETURN BEFORE THE FOLLOW-UP EMAIL GOT TO THE CALLER. THEREFORE, THE BOX WAS NOT SENT. THE CABLE IN THE ORIGINAL PACKAGING WAS RETURNED AND HAS NOT BEEN OPENED. THE FOREIGN OBJECT IS STILL IN PACKAGING UNTOUCHED. THE CALLER DID NOT TAKE PHOTOS AND THE PRODUCT WAS ALREADY PACKAGED FOR RETURN. THE OBJECT IS A SMALL BROWN PIECE OF PAPER/CARDBOARD. THE OBJECT APPEARED TO BE LOOSE, LOOKED LIKE A STRAY PIECE OF CARDBOARD. THE CABLE WAS NOT USED. THE EVENT WAS ASSESSED AS MDR REPORTABLE FOR FOREIGN MATERIAL INSIDE THE PACKAGING OUTSIDE OF SPECIFICATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17056900 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K090017. One submission often covers many models, so check the product and lot details in each record.
- Z-1230-2012 · Feb 9, 2012 · TerminatedCARTO 3 Systems, Product Code M-4800-01 The intended use of the CARTO 3 System is catheter-based cardiac electrophysiological (EP) procedures.
- Z-1839-2011 · Feb 15, 2011 · Terminated10 ft. Interface Cable, 10 Pin - Shielded Tip Pins to 12 Pin - Blue, Manufacturing Part Number 01287-09, Catalog Number D128709. This cable is used to connect an Auto 10 10-pole ca
- Z-0884-2011 · Oct 5, 2010 · TerminatedCARTO 3 System Interface Cable, 34-pin to 10-pin, Red, 10' - Part Number: D-1286-18; Catalog Number CR3410CT This product provides a signal interface between a Biosense Webster ele
- Z-2369-2012 · Nov 17, 2009 · TerminatedCARTO 3 V1.05(FG-5400-00). The CARTO 3 V1.05 System is intended for catheter-based atrial and ventricular mapping. The mapping system allows real-time display of cardiac maps in a
Other COMPUTER, DIAGNOSTIC, PROGRAMMABLE devices
- ZIO AT Patch A100A100XIrhythm Technologies, Inc. · Computer, Diagnostic, Programmable1 recall14 deaths629 reports
- CARTO 3 FG540000Biosense Webster (Israel) Ltd. · Computer, diagnostic, programmable1 death437 reports
- Sensis 10764561Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE5 recalls8 reports
- Sensis Vibe Hemo 11007641Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death22 reports
- Sensis Vibe Combo 11007642Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death6 reports
- Change Healthcare Cardiology Hemo 15.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable4 recalls1 report
- Change Healthcare Cardiology Hemo 15.0.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls1 death1 report
- Change Healthcare Cardiology Hemo 14.3.2Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page