Carto 3 CR3434CTRecalls & reported problems
Biosense Webster Inc · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10846835003871), received between Apr 2, 2019 and May 10, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Failure to Transmit Record” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K090017); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Transmit Record1
- Insufficient Device Problem Information1
- Overheating of Device1
- Pacing Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 10, 2024Overheating of Device; Failure to Transmit Record; Insufficient Device Problem Information; Overheating of Device; Failure to Transmit Record; Insufficient Device Problem Information
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) ABLATION PROCEDURE WITH A THERMOCOOL® SMART TOUCH® SF BI-DIRECTIONAL NAVIGATION CATHETER AND A CARTO® 3 SYSTEM INTERFACE CABLE AND BURNT MARKS WERE FOUND ON THE INSIDE PIN AREA. UPON PREPARING EVERYTHING FOR THE DOCTOR TO START THE PROCEDURE, ERROR 101 WAS NOTICED RELATED TO THE ABLATION CATHETER. THE SCRUB TECH WAS ASKED TO DISCONNECT IT AND THE PIU TOO WOULD ALSO BE UNPLUGGED. ONLY WHEN SHE DISCONNECT THE CATHETER FROM ITS CABLE THE SCRUB TECH IDENTIFIED BOTH THE CATHETER AND CONNECTOR HAD A BURNT MARK ON THE INSIDE PINS. BOTH THE CONNECTOR AND THE CATHETER WERE REPLACED. AFTER THAT, THE PROCEDURE WAS COMPLETED SUCCESSFULLY AND THERE WAS NO PATIENT CONSEQUENCE. ADDITIONAL INFORMATION WAS RECEIVED INDICATING THERE WERE NO SIGNS OF ANY VISIBLE FILE, FLAME OR SMOKE. IT WAS MORE SO THAT THE CONNECTOR EXPERIENCED A SHORT CIRCUIT OR SOMETHING THAT CAUSED BURN MARKS ON THE PINS WHERE IT JOINS THE CATHETER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19287385 ↗MalfunctionApr 2, 2019Pacing Problem; Pacing Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT AN ATRIAL FIBRILLATION (AFIB) PROCEDURE WITH A CARTO® 3 SYSTEM INTERFACE CABLE AND AN ISSUE OF INADVERTENT PACING OCCURRED. IT WAS DESCRIBED THAT THE CARTO® 3 SYSTEM WAS DISPLAYING NOISE ON THE ELECTROCARDIOGRAM (ECG) SIGNALS. IT WAS ALSO REPORTED THE ABLATION CATHETER AND THE CATHETER CONNECTED TO THE 20A PORT WERE DISPLAYING PACING DESPITE NO PACING BEING ACTIVE AND NO PACING CHANNELS BEING OPEN. ALL CABLES WERE DISCONNECTED FROM THE PATIENT INTERFACE UNIT (PIU) AND BOTH THE PATIENT INTERFACE UNIT (PIU) AND WORKSTATION WERE REBOOTED. THE PATIENT INTERFACE UNIT (PIU) BOOTED UP NORMALLY. WHEN THE ABLATION CABLE WAS CONNECTED TO THE PATIENT INTERFACE UNIT (PIU) ALL ECG SIGNALS WERE LOST, HOWEVER, ONCE DISCONNECTED FROM THE PATIENT INTERFACE UNIT (PIU), THE ECG SIGNAL RETURNED. THE CUSTOMER WAS ADVISED TO REPLACE THE CARTO® 3 SYSTEM INTERFACE CABLE AND THEN THE ISSUES RESOLVED. THE PROCEDURE WAS CONTINUED. NO PATIENT CONSEQUENCE WAS REPORTED. MULTIPLE ATTEMPTS HAVE BEEN MADE TO OBTAIN CLARIFICATION TO THIS COMPLAINT. HOWEVER, NO FURTHER INFORMATION HAS BEEN MADE AVAILABLE. THE CUSTOMER¿S REPORTED ISSUE OF INADVERTENT PACING IS CONSIDERED A REP
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8473543 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K090017. One submission often covers many models, so check the product and lot details in each record.
- Z-1230-2012 · Feb 9, 2012 · TerminatedCARTO 3 Systems, Product Code M-4800-01 The intended use of the CARTO 3 System is catheter-based cardiac electrophysiological (EP) procedures.
- Z-1839-2011 · Feb 15, 2011 · Terminated10 ft. Interface Cable, 10 Pin - Shielded Tip Pins to 12 Pin - Blue, Manufacturing Part Number 01287-09, Catalog Number D128709. This cable is used to connect an Auto 10 10-pole ca
- Z-0884-2011 · Oct 5, 2010 · TerminatedCARTO 3 System Interface Cable, 34-pin to 10-pin, Red, 10' - Part Number: D-1286-18; Catalog Number CR3410CT This product provides a signal interface between a Biosense Webster ele
- Z-2369-2012 · Nov 17, 2009 · TerminatedCARTO 3 V1.05(FG-5400-00). The CARTO 3 V1.05 System is intended for catheter-based atrial and ventricular mapping. The mapping system allows real-time display of cardiac maps in a
Other COMPUTER, DIAGNOSTIC, PROGRAMMABLE devices
- ZIO AT Patch A100A100XIrhythm Technologies, Inc. · Computer, Diagnostic, Programmable1 recall14 deaths629 reports
- CARTO 3 FG540000Biosense Webster (Israel) Ltd. · Computer, diagnostic, programmable1 death437 reports
- Sensis 10764561Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE5 recalls8 reports
- Sensis Vibe Hemo 11007641Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death22 reports
- Sensis Vibe Combo 11007642Siemens Healthcare GmbH · COMPUTER, DIAGNOSTIC, PROGRAMMABLE4 recalls1 death6 reports
- Change Healthcare Cardiology Hemo 15.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable4 recalls1 report
- Change Healthcare Cardiology Hemo 15.0.1Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls1 death1 report
- Change Healthcare Cardiology Hemo 14.3.2Change Healthcare Canada Company · Computer, Diagnostic, Programmable3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page