Skip to content

Signia SIGPSHELLRecalls & reported problems

Covidien LP · Power Shell · Class 2

All models of Signia (16)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Signia Power Shell surgical stapler has 225 adverse event reports: 216 describe malfunctions, 8 describe injuries, and 1 report mentions a death. Many reports describe the shell not closing or locking, a loose connection between the shell and adapter, or the device being difficult to set up before use. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
228
Deaths reported
1
Injuries reported
9
Recalls naming it
0

Summary

The FDA's MAUDE database contains 228 adverse event reports that list this exact device (DI 10884521543799), received between May 30, 2017 and Sep 21, 2026 — classified as 1 death, 9 injuries, 218 malfunctions.

The most frequently reported specific device problem is “Unraveled Material” (68 reports).

14 other recalls cover devices cleared under the same FDA submission (K160176, K201672); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 2 reportsFeb 2024: 2 reportsMar 2024: 3 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 2 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 4 reportsOct 2024: 2 reportsNov 2024: 2 reportsDec 2024: 0 reportsJan 2025: 5 reportsFeb 2025: 0 reportsMar 2025: 4 reportsApr 2025: 1 reportsMay 2025: 6 reportsJun 2025: 2 reportsJul 2025: 5 reportsAug 2025: 4 reportsSep 2025: 2 reportsOct 2025: 3 reportsNov 2025: 0 reportsDec 2025: 4 reportsJan 2026: 4 reportsFeb 2026: 2 reportsMar 2026: 5 reportsApr 2026: 2 reportsMay 2026: 1 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 3 reportsSep 2026: 2 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520266
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unraveled Material68
  • Device Difficult to Setup or Prepare65
  • Break18
  • Adverse Event Without Identified Device or Use Problem17
  • Detachment of Device or Device Component16
  • Device Displays Incorrect Message11
  • Failure to Fire10
  • Complete Loss of Power8

Patient problems

  • No Clinical Signs, Symptoms or Conditions129
  • No Consequences Or Impact To Patient42
  • No Known Impact Or Consequence To Patient26
  • No Patient Involvement16
  • No Code Available13
  • Insufficient Information12
  • Tissue Damage4
  • Failure to Anastomose2

Recent adverse event reports

The 25 most recent of 228 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 21, 2026Unraveled Material

    It was reported that during a procedure, the control shell could not close as expected. There was no patient injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50839526 ↗
  • MalfunctionSep 21, 2026Unraveled Material

    It was reported that during a procedure, the power control shell could not be locked. A new shell was used to resolve the issue. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50836281 ↗
  • MalfunctionAug 26, 2026Human-Device Interface Problem

    It was reported that during a rectotomy, while on high anterior resection, after the firing, the jaw opened fully; however, the cart ridge did not return to the neutral position, even when the up button on the center control was long-pressed or the left/right buttons were pressed. Manual adapter tools were used to resolve the issue. There was no patient injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50446981 ↗
  • InjuryAug 22, 2026Adverse Event Without Identified Device or Use Problem

    According to a clinical study, on (b)(6)2026, a week following a robotic low anterior resection for a rectal mass involving a powered surgical handle, circular adapter, power shell, and circular reload, the patient presented with abdominal pain, syncope, vomiting, fever, and tachycardia. The patient was found to have an atrial fibrillation with rapid ventricular response, anastomotic leak of the intestine, bowel perforation, and intra-abdominal abscess requiring emergent diagnostic laparoscopy, abscess drainage, laparoscopic partial colectomy, and permanent end colostomy. The event resulted in new inpatient hospitalization from (b)(6) 2026. The investigator assessed the event as possibly related to the study procedure and study device. The sponsor assessed a causal relationship to the study procedure and a possible relationship to the study device.

    Patient problems: Abdominal Pain; Abscess; Atrial Fibrillation; Bowel Perforation; Failure to Anastomose; Fever; Syncope/Fainting; Tachycardia; Vomiting

    MAUDE report 50388710 ↗
  • MalfunctionAug 12, 2026Unraveled Material

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50219064 ↗
  • MalfunctionJun 4, 2026Unraveled Material

    ACCORDING TO THE REPORTER, DURING A LAPAROSCOPIC ROUX-EN-Y DIVIDED GASTRIC BYPASS AND LAPAROSCOPIC HIATAL HERNIA REPAIR, THE SHELL WOULD NOT LOCK.

    Patient problems: Insufficient Information

    MAUDE report 25403146 ↗
  • MalfunctionMay 18, 2026Device Difficult to Setup or Prepare; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A PROCEDURE BUT PRIOR TO PATIENT CONTACT, A LOOSE CONNECTION FROM THE SHELL TO THE ADAPTER WERE OBSERVED AND THE ADAPTER WAS DISCONNECTED FROM THE SHELL AND RECONNECTED, AND THE CARTRIDGE WAS DISCONNECTED AND RECONNECTED, AFTER WHICH THE SYSTEM WORKED AGAIN. LATER IN THE PROCEDURE, THE ADAPTER FELL OFF THE SHELL AND WAS RECONNECTED AGAIN, AND IT THEN WORKED FOR THE REMAINDER OF THE PROCEDURE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25209810 ↗
  • MalfunctionApr 6, 2026Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, PREOPERATIVELY, LOOSE CONNECTION FROM SHELL TO ADAPTER. A NEW SHELL WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24795829 ↗
  • MalfunctionApr 6, 2026Unraveled Material

    IT WAS REPORTED THAT PREOPERATIVELY, THE SHELL DID NOT CLOSE. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24792460 ↗
  • MalfunctionMar 31, 2026Difficult to Insert; Unraveled Material

    IT WAS REPORTED THAT DURING SET-UP PRIOR TO PATIENT CONTACT WITH THE POWERED SHELL, THE INSERTION GUIDE DID NOT FIT AND THE POWER SHELL COULD NOT BE CLOSED. THE DEVICE WAS REPLACED. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24738219 ↗
  • MalfunctionMar 19, 2026Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, DURING A GASTROPLASTY, THE ADAPTER CAME LOOSE WHILE THE DOCTOR WAS POSITIONING THE LOAD FOR STAPLING. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24637418 ↗
  • MalfunctionMar 19, 2026Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, DURING A GASTROPLASTY, THE ADAPTER CAME LOOSE WHILE THE DOCTOR WAS POSITIONING THE LOAD FOR STAPLING. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24637395 ↗
  • MalfunctionMar 11, 2026Detachment of Device or Device Component

    ACCORDING TO THE REPORTER, DURING A PARTIAL PULMONARY RESECTION, ON ASSEMBLY, WHEN THE USER TRIED TO TAKE THE DEVICE OUT OF THE BLISTER PACK, IT WAS TAKEN OUT FROM THE PACK AS USUAL, AND THE SHELL BROKE INTO TWO. THE USER TOOK IT OUT WITH BOTH HANDS, SO NO STRONG FORCE WAS APPLIED. ANOTHER SHELL WAS USED AS SUBSTITUTE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24575233 ↗
  • MalfunctionMar 2, 2026Imprecision; Unraveled Material

    ACCORDING TO THE REPORTER, PRIOR TO USE, THE ENGAGEMENT OF THE SHELL TO THE POWERED HANDLE WAS STRANGE/IMPROPER AND THE SHELL COULD NOT BE CLOSED. A NEW POWERED SHELL WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24478528 ↗
  • MalfunctionFeb 17, 2026Unraveled Material

    IT WAS REPORTED THAT DURING THE PROCEDURE, THE SHELL WAS UNABLE TO CLOSE AS EXPECTED. THE ISSUE WAS RESOLVED BY REPLACING THE DEVICE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24369538 ↗
  • MalfunctionFeb 3, 2026Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, DURING A SINGLE PORT VIDEO-ASSISTED THORACOSCOPIC FOR PERIPHERAL LUNG LESIONS (VATS-PLL) LOBECTOMY, THE ADAPTER DETACHED FROM THE SHELL WITHOUT EXTERNAL FORCE. THE DEVICE WAS REPLACED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24255091 ↗
  • MalfunctionJan 29, 2026Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, PREOPERATIVELY, THE ADAPTER DOES NOT SEAT PROPERLY INTO THE CLAMSHELL. THE CONNECTION IS LOOSE. A NEW SHELL WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24217058 ↗
  • MalfunctionJan 22, 2026Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, DURING A GASTRECTOMY, DURING SETUP, THE ADAPTER GO SEPARATED FROM THE SHELL PRIOR TO FIRING. A MANUAL STAPLER WITH THE SAME RELOAD WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24152939 ↗
  • MalfunctionJan 16, 2026Unraveled Material

    ACCORDING TO THE REPORTER, THE ISSUE OF BEING UNABLE TO CLOSE POWERSHELL WAS ENCOUNTERED PREOPERATIVELY. A NEW SHELL WAS USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24093150 ↗
  • MalfunctionJan 7, 2026Device Difficult to Setup or Prepare; Insufficient Device Problem Information

    IT WAS REPORTED THAT PREOPERATIVELY, WHILE ON SET-UP, THE ADAPTER WAS AUTOMATICALLY CONNECTING AND DISCONNECTING TO THE POWER SHELL REPEATEDLY, AND THERE WAS A LOOSE CONNECTION FROM THE SHELL TO THE ADAPTER. A NEW SHELL WAS USED TO RESOLVE THE ISSUE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23998211 ↗
  • MalfunctionDec 29, 2025Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, DURING THE LAPAROSCOPIC LOW ANTERIOR RESECTION, WHEN ON FIRING AT THE RECTAL RESECTION, THE KNIFE WAS PULLED BACK ON ITS OWN WITHOUT COMPLETING THE FIRING. IT WAS CONFIRMED THAT THE CONNECTION PART OF THE ADAPTER AND THE SHELL WAS LOOSE. THE COMPONENTS WERE REATTACHED AS IT WAS. ADDITIONAL RESECTION WAS PERFORMED, AND ADDITIONAL SUTURING WAS DONE WITH A STAPLER TO RESOLVE THE ISSUE.

    Patient problems: Tissue Breakdown

    MAUDE report 23918763 ↗
  • MalfunctionDec 25, 2025Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, DURING A S6 SEGMENTAL RESECTION BUT BEFORE USING IT ON THE PATIENT, THE POWERED STAPLER WAS HANDED TO THE PHYSICIAN FROM THE SCRUB NURSE, THE ADAPTER SUDDENLY FELL OFF FROM THE SHELL. TO RESOLVE THE ISSUE, IT WAS RE-ATTACHED EVERYTHING AGAIN AND USED IT. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23892127 ↗
  • MalfunctionDec 17, 2025Connection Problem

    POWER SHELL NOT CONNECTING WITH BATTERY, HAD TO SWITCH SHELLS TO WORK.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23827470 ↗
  • MalfunctionDec 8, 2025Unraveled Material; Unraveled Material

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC GASTRECTOMY, BEFORE USE, THE POWER SHELL CANNOT BE CLOSED. ANOTHER HANDLE AND A NEW SHELL WERE TAKEN OUT AND USED WITHOUT ANY PROBLEMS. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23744116 ↗
  • MalfunctionOct 23, 2025Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare

    ACCORDING TO THE REPORTER, DURING THE THORACOSCOPIC PULMONARY RESECTION, DESPITE THE ADAPTER PROPERLY CONNECTED UNTIL IT CLICKED, IT DETACHED FROM THE SHELL DURING THE APPROACH. THERE WERE NO ERROR MESSAGES ON THE DISPLAY, ALL GREEN DISPLAY. THE ADAPTER AND SHELL WERE EACH REPLACED WITH NEW ONES TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23367864 ↗

FDA clearance and classification

Cleared through Special 510(k) K201672 on Jul 17, 2020 (decision: Substantially Equivalent). Submitted by Covidien as “Signia Stapler (with new software)”. The FDA review took 28 days. FDA record ↗

Cleared through 510(k) K160176 on Apr 26, 2016 (decision: Substantially Equivalent). Submitted by Covidien as “Signia Stapler”. The FDA review took 90 days. FDA record ↗

The FDA regulates product code GDW (staple, implantable) under 21 CFR 878.4750 as a Class II device. 21 CFR 878.4750 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K160176, K201672. One submission often covers many models, so check the product and lot details in each record.

  • Z-1228-2023 · Jan 25, 2023 · Open, Classified
    Tri-Staple 2.0 Black Intelligent Reload, Product Number SIG60AXT
  • Z-1836-2019 · May 17, 2019 · Open, Classified
    SIGNIA TRI-STAPLE 2.0 CURVED TIP 60MM MEDIUM/ THIC , SIG60CTAMT
  • Z-1830-2019 · May 17, 2019 · Open, Classified
    EGIA 60 CURVED TIP ART MED THICK SULU, EGIA60CTAMT
  • Z-1826-2019 · May 17, 2019 · Open, Classified
    EGIA 45 ARTICULATING MED THICK SULU, Item Code EGIA45AMT
  • Z-1829-2019 · May 17, 2019 · Open, Classified
    EGIA 60 ARTICULATING MED THICK SULU , EGIA60AMT
  • Z-1831-2019 · May 17, 2019 · Open, Classified
    EGIA45 CT AR MD THK REL, EGIA45CTAMT
  • Z-1828-2019 · May 17, 2019 · Open, Classified
    EGIA 60 ARTICULATING EXTRA THICK SULU, Item code EGIA60AXT
  • Z-1835-2019 · May 17, 2019 · Open, Classified
    SIGNIA TRI-STAPLE 2.0 CURVED TIP 45MM MEDIUM/ THIC , SIG45CTAMT
  • Z-1833-2019 · May 17, 2019 · Open, Classified
    SIGNIA TRI-STAPLE 2.0 BLACK 45MM EXTRA THICK RELOA, SIG45AXT
  • Z-1827-2019 · May 17, 2019 · Open, Classified
    EGIA 45 ARTICULATING XTRA THICK SULU, Item Code EGIA45AXT
  • Z-1834-2019 · May 17, 2019 · Open, Classified
    SIGNIA TRI-STAPLE 2.0 BLACK 60MM EXTRA THICK RELOA, SIG60AXT
  • Z-1825-2019 · May 17, 2019 · Open, Classified
    EGIA 30 ARTICULATING MED THICK SULU, Item Code EGIA30AMT
  • Z-1832-2019 · May 17, 2019 · Open, Classified
    SIGNIA TRI-STAPLE 2.0 30MM MEDIUM/ THICK RELOAD , SIG30AMT
  • Z-1237-2018 · Dec 13, 2017 · Terminated
    Signia" Power Handle (SIGPHANDLE, SIGNVAL1 and SIGVAL20 - Kits) The Signia" Power Handle, when used with Endo GIA" single-use reloads and Endo GIA" single-use reloads with Tri-Sta

Common questions about the Signia SIGPSHELL

Has the Signia SIGPSHELL been recalled?

No FDA recall record in our data names this exact device identifier (DI 10884521543799), based on the FDA recall file dated Nov 27, 2026. However, 14 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the Signia SIGPSHELL?

The FDA's MAUDE database lists 228 adverse event reports for this device, received between May 30, 2017 and Sep 21, 2026. In those reports, the most common specific device problems are “Unraveled Material” (68), “Device Difficult to Setup or Prepare” (65) and “Break” (18); the most common patient problems are “Tissue Damage” (4) and “Failure to Anastomose” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Signia SIGPSHELL?

1 report is classified as a death, 9 as injuries and 218 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Signia SIGPSHELL FDA approved?

It was cleared through 510(k) K160176 on Apr 26, 2016; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Signia SIGPSHELL, and is it still sold?

The FDA's device database lists Covidien LP as the company responsible for it (brand Signia, model SIGPSHELL). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other STAPLE, IMPLANTABLE devices

All STAPLE, IMPLANTABLE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page