EndoFLIP EF-322N (UDI 10884521809413)Recalls & reported problems

Covidien LP · Endolumenal Functional Lumen Imaging Probe · Class 2

Adverse event reports
15
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 10884521809413), received between Dec 20, 2022 and Jun 9, 2025 — classified as 15 malfunctions.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 3 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 2 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Device1
  • Device Damaged Prior to Use1
  • Device Difficult to Program or Calibrate1
  • Failure of Device to Self-Test1
  • Failure to Calibrate1
  • Inflation Problem1
  • Pressure Problem1
  • Therapeutic or Diagnostic Output Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions13
  • Cough1
  • Insufficient Information1

Recent adverse event reports

The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 9, 2025Inflation Problem

    THE DEVICE WILL TYPICALLY INFLATE A BALLOON CATHETER AND GIVE FEEDBACK ON THE PATIENTS MOTILITY. THIS PARTICULAR BALLOON CATHETER FAILED TO INFLATE WITH MULTIPLE ATTEMPTS. THIS EQUIPMENT DID NOT FUNCTIONING PROPERLY AND INCREASED THE TIME OF THE PROCEDURE AND THE AMOUNT OF TIMES THAT THE ESOPHAGUS WAS PASSED THROUGH WITH DEVICES. INCREASING THE RISK OF THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22166480 ↗
  • MalfunctionMay 28, 2025Device Difficult to Program or Calibrate; Device Difficult to Program or Calibrate

    IT WAS REPORTED THAT THE THREE CATHETERS FAILED PRE CHECK AND ONE BALLOON LEAKED. REPEATED EACH CATHETERS PRECHECK THREE TIMES. THERE WAS NO PATIENT AND USER HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22097240 ↗
  • MalfunctionMar 21, 2025

    THE PRE-CHECK OF SETUP THE PISTON SYRINGE STARTED TO FILL WITH AIR FROM THE LARGE BLACK SEAL. THE SYRINGE WAS REMOVED, AND THE AIR WAS REMOVED. THE DEVICE WAS SET UP USING THE SAME EQUIPMENT, AND THE PRE-CHECK WAS RESTARTED. WITH THE ATTEMPT, THE PISTON SYRINGE STARTED TO LEAK FLUID FROM THE BLACK SEAL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21662404 ↗
  • MalfunctionJan 29, 2025

    DEVICE PASSED INITIAL SETUP TEST, INFLATED BALLOON BEFORE PROCEDURE AND WOULD NOT DEFLATE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21262943 ↗
  • MalfunctionDec 5, 2024

    CATHETER PASSED TEST PRIOR TO USE, DURING PROCEDURE WHEN INSERTED INTO THE ESOPHAGUS AND INFLATED, BALLOON INFLATED BUT WOULD NOT REGISTER PRESSURE. AFTER SEVERAL ATTEMPTS, ANOTHER CATHETER WAS OPENED AND SET UP. THE NEWLY OPENED CATHETER FUNCTIONED APPROPRIATELY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20852356 ↗
  • MalfunctionDec 5, 2024

    ENDOFLIP MEASUREMENT CATHETER (MODEL #322N) FAILED UPON SET UP, DURING CALIBRATION ERROR CODE WAS GIVEN ON MONITOR. UNABLE TO USE CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20852329 ↗
  • MalfunctionMay 28, 2024

    CATHETER LEAKING WATER DURING PRIMING/CHECKING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19403800 ↗
  • MalfunctionMay 7, 2024

    DURING ENDOFLIP PROCEDURE (THE FUNCTIONAL LUMEN IMAGING PROBE (FLIP) WITH A VOLUME BASED BAROSTAT BAG), WAS PLACED AT THE LOWER ESOPHAGEAL SPHINCTER FOR THE POST-INTERVENTION ASSESSMENT OF ACHALASIA. THE BAROSTAT BAG/BALLOON WAS INFLATED WHILE INSERTED, BUT DID NOT REGISTER PRESSURES. ABLE TO OBTAIN MEASUREMENTS WITH THIS PARTICULAR BALLOON ONCE, BUT THE SECOND TIME IT DID NOT OPERATE PROPERLY. ANOTHER FLIP AND BALLOON WERE USED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19258845 ↗
  • MalfunctionMay 7, 2024

    PRIOR TO USING IN PROCEDURE, ENDOFLIP BALLOON WOULD NOT ZERO. NEW BALLOON WAS USED INSTEAD WITH NO PROBLEM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19258762 ↗
  • MalfunctionSep 13, 2023Device Damaged Prior to Use; Device Damaged Prior to Use

    ACCORDING TO THE REPORTER, THE TIP OF THE CATHETER FELL OFF OF THREE CATHETERS FROM THE SAME LOT NUMBER. ONE TIP CAME OFF IN THE PATIENT AND THE PATIENT COUGH IT UP. THERE WAS NO PATIENT OR USER HARM.

    Patient problems: Cough

    MAUDE report 17740767 ↗
  • MalfunctionApr 14, 2023Therapeutic or Diagnostic Output Failure

    PRE-CHECK OF THE CATHETER FAILED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16742570 ↗
  • MalfunctionJan 31, 2023Pressure Problem

    IT WAS REPORTED THAT DURING THE PROCEDURE, RN NOTED THE PRESSURE READING FOR THE ENDO FLIP BALLOON WAS READING ABNORMALLY HIGH AT 200. THE PRESSURE READING SHOULD HAVE BEEN 20 OR BELOW. RN NOTIFIED THE PHYSICIAN OF THE PRESSURE READING. THE DECISION WAS MADE TO STOP THE PROCEDURE AND OBTAIN A NEW ZERO-PRESSURE READING WITH THE CURRENT CATHETER. THE PRESSURE READING DIDN'T CHANGE AFTER HAVING THE MACHINE CALCULATE ZERO PRESSURE A SECOND TIME. ENDO FLIP CATHETER WAS REMOVED FROM SERVICE. A NEW CATHETER WAS OBTAINED AND THE PROCEDURE CONTINUED WITHOUT INCIDENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16271168 ↗
  • MalfunctionJan 31, 2023Failure to Calibrate

    NEW ENDO FLIP 16CM NASAL TIP CONNECTED TO ENDO FLIP MACHINE. WOULD NOT CALIBRATE, MD STATES THAT IT WAS A PROBE FAILURE AND TO REMOVE IT FROM SERVICE. THIS OCCURRED BEFORE THE PATIENT ENTERED THE PROCEDURE ROOM. ANOTHER NEW ENDO FLIP 16CM NASAL TIP WAS OBTAINED FOR THE PROCEDURE AND CALIBRATED APPROPRIATELY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16270980 ↗
  • MalfunctionJan 31, 2023Failure of Device to Self-Test

    ENDOFLIP 16CM NASAL TIP BALLOON CATHETER DID NOT PASS PRECHECK. FAILED EQUIPMENT WAS NOT USED ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16270947 ↗
  • MalfunctionDec 20, 2022Defective Device

    IT WAS REPORTED THAT WHILE SETTING UP THE ENDOFLIP CATHETER 16CM NASAL TIP FOR USE DURING THE PROCEDURE, THE MEDTRONIC ENDOFLIP MACHINE NOTED THE CATHETER TO BE DEFECTIVE DURING THE INITIAL DIAGNOSTIC ANALYSIS. THE CATHETER WAS REMOVED FROM THE MACHINE AND A NEW CATHETER WAS PLACED.

    Patient problems: Insufficient Information

    MAUDE report 16014111 ↗

Other SYSTEM, GASTROINTESTINAL MOTILITY (ELECTRICAL) devices

All SYSTEM, GASTROINTESTINAL MOTILITY (ELECTRICAL) devices →