Valleylab E1564 (UDI 10884524000206)Recalls & reported problems

Covidien LP · Ball Electrode · Class 2

All models of Valleylab (97)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10884524000206), received between Nov 5, 2018 and Jun 9, 2025 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Melted” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Melted4
  • Peeled/Delaminated4
  • Adverse Event Without Identified Device or Use Problem1
  • Detachment of Device or Device Component1
  • Material Fragmentation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Consequences Or Impact To Patient2
  • Burn(s)1
  • Unspecified Tissue Injury1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 9, 2025Melted; Peeled/Delaminated; Melted; Peeled/Delaminated

    ACCORDING TO THE REPORTER DURING A LOOP ELECTROSURGICAL EXCISION PROCEDURE (LEEP), THE ELECTRODE HAD AN ISSUE. A NEW ELECTRODE WAS USED TO COMPLETE THE PROCEDURE. PHOTO WAS SUBMITTED SHOWING ELECTRODE INSULATION WAS DAMAGED AND MELTED. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22171791 ↗
  • InjuryJan 20, 2023Melted; Peeled/Delaminated; Melted; Peeled/Delaminated

    ACCORDING TO THE REPORTER, INTRA-OPERATIVELY, THE SHIELD ON THE ELECTRODE WAS MELTING. THE PATIENT HAD TISSUE DAMAGED OR UNEXPECTED TISSUE LOSS. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: Unspecified Tissue Injury

    MAUDE report 16215877 ↗
  • MalfunctionJan 17, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ACCORDING TO THE REPORTER, AFTER THE CONE BIOPSY OF CERVIX: DILATION AND CURETTAGE, THE PHYSICIAN AND NURSE NOTICED THAT THE PATIENT DISCOVERED A BURN IN INNER VAGINAL WALL WHILE SURGERY STILL ONGOING. THICKENED MONSEL WAS APPLIED POST-OPERATIVELY TO BURN AREA. IT WAS NOTED THAT THE BURN WAS CAUSED BY THE INSULATION ELECTRODE BALL AND A COMPETITOR¿S DIATHERMY LOOP. ONLY THOSE TWO AND SPECULUM TOUCHED PATIENT INNER VAGINAL WALL.

    Patient problems: Burn(s)

    MAUDE report 13266076 ↗
  • MalfunctionMar 18, 2021Melted; Detachment of Device or Device Component; Melted; Detachment of Device or Device Component

    ACCORDING TO THE REPORTER, DURING A PROCEDURE, PART OF THE DEVICE'S SHEATH MELTED INTO THE PATIENT'S TISSUE AND HAD TO BE RETRIEVED. DIATHERMY USED WAS 40/40, AFTER CONTINUOUS ACTIVATION SHEATH MELTED BUT WAS RETRIEVED USING FORCEPS AND NO X-RAY PROCEDURE WAS REQUIRED. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11515825 ↗
  • MalfunctionJul 22, 2020Peeled/Delaminated; Peeled/Delaminated

    ACCORDING TO THE REPORTER, DURING A CERVICAL ABLATION, WHILE USING THE DEVICE AT COAGULATION SETTING OF 50, THE SURGEON NOTICED THE APPEARANCE OF THE ELECTRODE WHEREIN THE COATING WAS MELTING. NOTHING FELL INTO THE PATIENT'S CAVITY. THEY DISCONTINUED USING THE ELECTRODE, AND REPLACED IT WITH A NEW ONE. THEY TURNED DOWN THE OUTPUT TO 40, AND CONTINUED THE CASE NORMALLY. BIOMED CHECKED OUTPUTS OF GENERATOR AND CONFIRMED THAT IT WAS WORKING CORRECTLY. THERE WAS NO PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10306799 ↗
  • MalfunctionNov 5, 2018Material Fragmentation; Melted; Peeled/Delaminated; Material Fragmentation; Melted; Peeled/Delaminated

    ACCORDING TO THE REPORTER, INTRA-OPERATIVELY, THE DEVICE'S INSULATION MELTED AND A PART OF THE DEVICE FELL ON THE PATIENT¿S CAVITY, BUT WAS FULLY RETRIEVED. THERE WAS NO PATIENT INJURY. NO FURTHER INFORMATION AVAILABLE AT THIS TIME.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8038791 ↗

Other ELECTROCAUTERY, GYNECOLOGIC (AND ACCESSORIES) devices

All ELECTROCAUTERY, GYNECOLOGIC (AND ACCESSORIES) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page