Equinoxe 311-07-05Recalls & reported problems
Exactech, Inc. · IMPACTOR · Class 2
All models of Equinoxe (305)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10885862084316), received between Nov 14, 2020 and Jul 30, 2021 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
10 other recalls cover devices cleared under the same FDA submission (K042021, K140063); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break4
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 30, 2021Break; Break
AS REPORTED, DURING A PROCEDURE, THE IMPACTOR TIP BROKE OFF WHILE IMPACTING FINAL HUMERAL HEAD. NO PIECES LEFT IN PATIENT, NO DELAY TO SURGERY OR ADVERSE EFFECTS TO THE PATIENT. THE DEVICE WILL BE RETURNED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12251883 ↗MalfunctionJul 16, 2021Break; Break
AS REPORTED, DURING THE PROCEDURE, THE IMPACTOR TIP BROKE OFF THE HANDLE WHILE IMPACTING HUMERAL HEAD. NOTHING FELL IN THE SURGICAL SITE, NO DELAY TO SURGERY, NO ADVERSE EFFECTS TO PATIENT. PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT. DEVICE WILL RETURN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12181996 ↗MalfunctionJun 9, 2021Break; Break
AS REPORTED, THE SURGEON WAS USING THE INSTRUMENT IN AN ANATOMIC CASE ON THIS MALE PATIENT, HE USED A MALLET TO IMPACT THE HEAD ONTO THE STEM AND WHEN HE TOOK THE IMPACTOR HEAD AWAY FROM THE HEAD HE NOTICED IT HAS BROKEN AT THE JUNCTION OF THE IMPACTOR HEAD AND THE HANDLE. THE DEVICE WILL RETURN FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11964409 ↗MalfunctionNov 14, 2020Break; Break
AS REPORTED, DURING A SHOULDER PROCEDURE ON A 30 Y/O MALE, THE FINAL STEM 13 + REPLICATOR 1.5 WERE MOUNTED TOGETHER ON A BACK TABLE ASSEMBLY. THE HUMERAL HEAD, SHORT, 47MM WAS IMPACTED AS WELL ON THE BACK TABLE. THIS CONSTRUCT WAS THEN IMPACTED IN THE HUMERUS, THE STEM WAS STUCK 2 CM HIGHER THAN THE CUT. DURING THE IMPACTION, THE HUMERAL HEAD IMPACTOR TIP WAS BROKEN. A FEMORAL HEAD IMPACTOR PRESENT IN THE HOSPITAL HAS BEEN CONSEQUENTLY USED TO GO ON THE SURGERY. PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT. DEVICES ARE TO BE RETURNED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10841089 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K042021, K140063. One submission often covers many models, so check the product and lot details in each record.
- Z-0535-2026 · Sep 5, 2025 · Open, ClassifiedBrand Name: Equinoxe Ergo Product Name: Adjustable Angle rTSA Reamer, 42mm Model/Catalog Number: 321-59-42 Software Version: N/A Product Description: rTSA Reamer, 42mm Component: N
- Z-0537-2026 · Sep 5, 2025 · Open, ClassifiedBrand Name: Equinoxe Ergo Product Name: Ergo Augments Pilot Tip Converter Model/Catalog Number: 301-11-11 Software Version: N/A Product Description: Pilot Tip Converter Piece Compo
- Z-0536-2026 · Sep 5, 2025 · Open, ClassifiedBrand Name: Equinoxe Ergo Product Name: Adjustable Angle rTSA Reamer, 46mm Model/Catalog Number: 321-59-46 Software Version: N/A Product Description: rTSA Reamer, 46mm Component: N
- Z-1402-2024 · Mar 6, 2024 · Open, ClassifiedExactech Equinoxe GLENOID,KEELED, CEMENTED, Mates with 38, 41, 44 head, alpha curvature, Sizes: a), Small, Item Number 314-01-02; b) Medium, Item number 314-01-03; c) Large, Item
- Z-1404-2024 · Mar 6, 2024 · Open, ClassifiedExactech Equinoxe GLENOID,KEELED, CEMENTED, mates with 47, 50, 53 head, beta curvature, Sizes: a) Small, Item Number 314-02-02, b) Medium, Item Number 314-02-03, c) Large, Item Nu
- Z-1403-2024 · Mar 6, 2024 · Open, ClassifiedExactech Equinoxe GLENOID,KEELED, CEMENTED, mates with 47, 50, 53 head, beta curvature, Sizes: a) Small, Item Number 314-01-12, b) Medium, Item Number 314-01-13, c) Large, Item Nu
- Z-1405-2024 · Mar 6, 2024 · Open, ClassifiedExactech Equinoxe GLENOID,KEELED, CEMENTED,47, 50, 53 head, beta curvature, Sizes: a) Small, Item Number 314-02-12, b) Medium, Item Number 314-02-13, c) Large, Item Number 314-02
- Z-0884-2021 · Nov 9, 2020 · Open, ClassifiedEquinoxe Humeral Stem, Primary, Press Fit, 11mm
- Z-1459-2015 · Feb 13, 2015 · TerminatedEquinoxe 44mm Short Humeral Head Catalog Number 310-01-44. Orthopedic shoulder implant component.
- Z-2115-2012 · Jun 15, 2012 · TerminatedEquinoxe Anatomic Replicator Plate Intended for Primary and Reverse Total Shoulder Arthroplasty
Other PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED devices
- DJO SURGICAL 509-02-032Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED364 reports
- DELTA XTEND 130790036Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED171 reports
- DELTA XTEND 130770018Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED159 reports
- TRIGEN 71118200Smith & Nephew, Inc. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED123 reports
- DJO SURGICAL 509-02-432Encore Medical, L.P. · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED119 reports
- DELTA XTEND 130738206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED116 reports
- COMPREHENSIVE SHOULDER SYSTEM 113633Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED2 recalls4 reports
- DELTA XTEND 130742206Depuy (Ireland) · PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED99 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page