Skip to content

Vantage 350-22-64Recalls & reported problems

Exactech, Inc. · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10885862293442), received between Apr 24, 2025 and Apr 24, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Unstable” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

5 other recalls cover devices cleared under the same FDA submission (K152217); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Aug 30, 2021Open, Classified

    Inserts were packaged in vacuum bags that lacked an additional oxygen barrier layer.

    Z-0024-2022 · Root cause: Process control · FDA record ↗

Most reported problems

Device problems

  • Unstable1

Patient problems

  • Cyst(s)1
  • Discomfort1
  • Joint Laxity1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 24, 2025Unstable; Unstable

    IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL TOTAL ANKLE REPLACEMENT ON THE RIGHT SIDE. SUBSEQUENTLY, THE PATIENT EXPERIENCED A CYST FORMATION, FREQUENT INVERSION EVENTS DUE TO PERSISTENT ANKLE INSTABILITY AND DISCOMFORT WHILE AMBULATING. ENLARGING CYST FORMATION UNDER TIBIA TRAY LEADING TO POTENTIAL SUBSIDENCE. AS A RESULT, APPROXIMATELY 6 YEARS AFTER INITIAL REPLACEMENT, THE PATIENT UNDERWENT A RIGHT ANKLE REVISION. NO FURTHER IMPACT TO THE PATIENT WAS REPORTED. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: Cyst(s); Discomfort; Joint Laxity

    MAUDE report 21901994 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K152217. One submission often covers many models, so check the product and lot details in each record.

  • Z-0587-2024 · Nov 21, 2023 · Open, Classified
    Exactech Vantage Ankle System, Catalog Numbers: a) 350-21-04, b) 350-22-03
  • Z-2926-2020 · Aug 10, 2020 · Open, Classified
    The Vantage Total Ankle Tibial Insert, Fixed Bearing, Size 4, Right 10mm.
  • Z-2966-2018 · Jul 13, 2018 · Terminated
    Tibial Alignment Guide, REF 351-10-00 Vantage Fixed Ankle system components for ankle replacements.
  • Z-0200-2018 · May 16, 2017 · Terminated
    Vantage Total Ankle Tibial Insert, Fixed Bearing, 7 mm, Left, Size 3. Exactech Inc., Intended for patients with ankle joints damage by severe rheumatoid, post-traumatic, or dege
  • Z-0201-2018 · May 16, 2017 · Terminated
    Vantage Total Ankle Tibial Insert, Fixed Bearing, 10 mm, Left, Size 3. Exactech Inc. Intended for patients with ankle joints damage by severe rheumatoid, post-traumatic, or degene

Other Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer devices

All Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page