GRYPHON Flex 208955Recalls & reported problems

Medos International Sàrl · GRYPHON Flex Knotless PEEK Anchor PEEK Anchor STRAIGHT · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10886705032488), received between Jul 11, 2024 and Sep 25, 2026 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Device-Device Incompatibility2
  • Product Quality Problem1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 25, 2026Product Quality Problem; Use of Device Problem

    It was reported that during a right shoulder Bankart repair shoulder procedure, it was observed that the threader tab of the GRYPHON FLEX PEEK STRAIGHT device was missing from the implant. It was reported that a threader tab from a previous implant was used to load the suture onto the implant. During visual inspection of a photo that was received found the inserter outside of the packing without the kite assembled. It was reported that there was no delay in the procedure due to the event. There were no adverse consequences to the patient. No additional information could be provided.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50896172 ↗
  • MalfunctionSep 5, 2024Break; Break

    IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE THE GRYPHON FLEX PEEK STRAIGHT DEVICE DURING IMPLANT INSERTION PROCEDURE THE FLEXIBLE NITINOL TIP WAS BROKEN. PATIENT WAS NOT HARMED AND MINIMAL TIME WAS ADDED TO THE CASE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20148247 ↗
  • MalfunctionJul 11, 2024Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED BY SALES REP VIA EMAIL THAT DURING LABRAL REPAIR PROCEDURE ON (B)(6) 2024 USING THE GRYPHON FLEX PEEK STRAIGHT DEVICE AFTER TENSIONING AND INSERTING ANCHOR, THE LEVER WOULD NOT RELEASE IN ORDER TO REMOVE INSERTER. ACCRORDING TO THE REPORTER THE SURGEON HAD TO TWIST THE INSERTER TO REMOVE AND WAS NEVER ABLE TO RELEASE THE LEVEL, IT WAS VERY DIFFICULT TO REMOVE THE INSERTER AND A MALLET WAS USED TO REMOVE THE INSERTER. THE SURGEON WAS ABLE TO REMOVE INSERTER AND COMPLETE THE CASE WITHOUT ANY COMPLICATION. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. DEVICE WAS DISPOSED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19720148 ↗
  • MalfunctionJul 11, 2024Break; Device-Device Incompatibility; Break; Device-Device Incompatibility

    IT WAS REPORTED BY THE SALES REP THAT DURING A LABRAL REPAIR PROCEDURE ON (B)(6) 2024 IT WAS DISCOVERED THAT WHILE USING THE GRYPHON FLEX PEEK STRAIGHT, AFTER TENSIONING AND INSERTING ANCHOR, THE LEVER WOULD NOT RELEASE IN ORDER TO REMOVE INSERTER. THE SURGEON CONTINUE TO TRY TO RELEASE THE LEVER BUT IT BROKE OFF THE INSERTER HANDLE. THE SURGEON WAS ABLE TO REMOVE INSERTER AND COMPLETE THE CASE WITHOUT ANY COMPLICATION. THERE WAS NOT ADVERSE COMPLICATION TO THE PATIENT. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19718054 ↗

Other Fastener, fixation, nondegradable, soft tissue devices

All Fastener, fixation, nondegradable, soft tissue devices →