NA 03.010.028Recalls & reported problems

Synthes GmbH · 15.0MM CANNULATED DRILL BIT LARGE QC/280MM · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10886982067029), received between Jan 6, 2017 and Mar 2, 2026 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Contamination /Decontamination Problem2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Known Impact Or Consequence To Patient2

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 2, 2026Contamination /Decontamination Problem

    IT WAS REPORTED THAT THE FEMORAL RECON NAIL SLEEVES (GOLD RECON) AND AN OPENING DRILL BIT WERE BEING HELD BY SPD BECAUSE OF UNCERTAINTY REGARDING THEIR CLEANLINESS. THE SPD MANAGER REPORTED FINDING RESIDUE INTERNALLY ON THE GOLD SLEEVES AND THE DRILL BIT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24490398 ↗
  • MalfunctionMar 2, 2026Contamination /Decontamination Problem

    IT WAS REPORTED THAT THE FEMORAL RECON NAIL SLEEVES (GOLD RECON) AND AN OPENING DRILL BIT WERE BEING HELD BY SPD BECAUSE OF UNCERTAINTY REGARDING THEIR CLEANLINESS. THE SPD MANAGER REPORTED FINDING RESIDUE INTERNALLY ON THE GOLD SLEEVES AND THE DRILL BIT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24490395 ↗
  • MalfunctionJan 19, 2018Break; Break

    IT WAS REPORTED THAT AN OPEN DRILL BIT BROKE DURING A LATERAL ENTRY FEMORAL NAIL ON (B)(6) 2017. THE DRILL BIT WAS REPORTED TO HAVE BROKEN AS THE SURGEON WAS ATTACHING IT TO THE REAMER. THE PART THAT ATTACHES TO THE REAMER BROKE OFF CAUSING AN ESTIMATED TWO (2) MINUTE DELAY IN SURGERY AS THE SURGEON SWITCHED OVER TO A NEW DRILL BIT. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH ANOTHER DRILL BIT. THE PATIENT OUTCOME WAS REPORTED AS PERFECT. CONCOMITANT DEVICES REPORTED: 3.2 MM GUIDE WIRE (PART 357.399, LOT UNKNOWN, QUANTITY 1). 22.0 MM/17.0 MM PROTECTION SLEEVE (PART 357.410, LOT UNKNOWN, QUANTITY 1). THIS IS REPORT 1 OF 1 FOR (B)(4).

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7206334 ↗
  • MalfunctionJan 6, 2017Break; Break

    IT WAS REPORTED THAT DURING A FEMORAL INTRAMEDULLARY NAIL PROCEDURE ON (B)(6) 2016, AS THE SURGEON WAS DRILLING INTO THE CANAL STUMP OF THE FEMUR THE CONNECTION TO THE DRILL BIT BROKE AT THE STEP DOWN WHERE THE DRILL BIT IS CONNECTED TO THE STRYKER SYSTEM 7 DRILL (WHICH IS AT THE COUPLING END OF THE DRILL BIT). A BACKUP DRILL WAS AVAILABLE AND THE SURGEON WAS ABLE TO COMPLETE THE PROCEDURE WITHOUT FURTHER COMPLICATIONS. THERE WAS NO SURGICAL TIME DELAY AND NO PATIENT HARM REPORTED. THE PATIENT STATUS WAS STABLE. THIS COMPLAINT CONTAINS ONE DEVICE. THIS REPORT IS 1 OR 1 FOR (B)(4).

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6230711 ↗