NA 03.120.041Recalls & reported problems
Synthes GmbH · 2.8MM 3-FLUTED DRILL BIT QC/200MM · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10886982074294), received between Jun 21, 2018 and Aug 18, 2023 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break4
- Material Fragmentation1
Patient problems
- No Patient Involvement2
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 18, 2023Break; Break
DEVICE REPORT FROM DEPUY SYNTHES REPORTS AN EVENT IN COLOMBIA AS FOLLOWS: IT WAS REPORTED THAT DURING A PROCEDURE ON (B)(6) 2023, AFTER PERFORMING DRILLING FOR A 3.5MM SCREW, WHEN REMOVING THE DRILL BIT FROM THE BONE, IT CAME OUT INCOMPLETE, THEREFORE, THE FRAGMENT COULD NOT BE RECOVERED AND REMAINED INSIDE THE PATIENT. THERE WAS NO SURGICAL DELAY AND NO PATIENT COMPLICATIONS DUE TO THE REPORTED EVENT. THIS REPORT IS FOR ONE (1) 2.8MM 3-FLUTED DRILL BIT QC/200MM. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17573399 ↗MalfunctionMay 17, 2019Break; Break
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE, A DRILL BIT WAS FOUND BROKEN DURING DECONTAMINATION. THERE WERE NO PATIENT AND PROCEDURE INVOLVEMENT. THIS REPORT IS FOR ONE (1) 2.8MM 3-FLUTED DRILL BITQC/200MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Patient Involvement
MAUDE report 8619979 ↗InjuryOct 5, 2018Break; Material Fragmentation; Break; Material Fragmentation
CONCOMITANT DEVICE: PLATE (PART: UNKNOWN, LOT: UNKNOWN, QUANTITY: 1).
Patient problems: Foreign Body In Patient
MAUDE report 7939446 ↗MalfunctionJun 21, 2018Break; Break
DEVICE REPORT FROM SYNTHES EUROPE REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE DRILL BIT WAS FOUND BROKEN DURING DECONTAMINATION AT THE STERILE DEPARTMENT. THERE IS NO REPORTED PATIENT OR PROCEDURE INVOLVEMENT. THIS REPORT IS FOR A 2.8MM 3-FLUTED DRILL BIT QC/200MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Patient Involvement
MAUDE report 7626587 ↗
Other BIT, DRILL devices
- QUICKSET 2274-25-500Depuy Orthopaedics, Inc. · BIT, DRILL1,985 reports
- QUICKSET 2274-35-500Depuy Orthopaedics, Inc. · BIT, DRILL770 reports
- QUICKSET 2274-30-500Depuy Orthopaedics, Inc. · BIT, DRILL761 reports
- NA 03.037.022Synthes GmbH · BIT, DRILL339 reports
- NA 323.062Synthes GmbH · BIT, DRILL309 reports
- QUICKSET 2274-56-000Depuy (Ireland) · BIT, DRILL275 reports
- QUICKSET 2274-45-500Depuy Orthopaedics, Inc. · BIT, DRILL211 reports
- LCS 2366-83-000Depuy (Ireland) · BIT, DRILL207 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page